Features
High sensitivity and reliable performance; Built-in transceiver antenna for maximum performance; Maximum effective distance up to 1000mm; Less than 100ms decoding time; Low power dissipation with single power supply; Multiple output format optional; Built-in buzzer; Built-in external LED control; Potted for environmental protection.
3. Specifications
Power Requirements +12Volts linear regulated DC at 200mA typical, 250mA max. Interface Wiegand or other optional
Typical Maximum Read Range Range 1000mm with ISO card
(In ideal conditions)
Frequency 125KHz typical
Transponder Read Only
Audio/visual Indication Buzzer output with external
LED control
4. Interface
Color | Description |
Red | +12VDC |
Black | GND |
Green | DATA0 |
White | DATA1 |
Brow | HOLD |
Yellow | External LED control(Internal 2K pulled-up) |
5. Trouble Shooting
When powered up, LCR-100 long range reader take a self-test to ensure the best reading performance with the buzzer beeping continually. When the self-test ends, the buzzer will give out a long beep and the LCR-100 enter the normal working mode. If the buzzer continue beeping without stop for a long time, please turn off the power and check out the environment and power supply to ensure locating the LCR-100 in a good working condition. In case of problems the following procedure should be followed:
Failure to finish self-test with the buzzer beeping continually or with a short reading distance
1) Turn off the power to the Rhombus100;
2) Check the power input connections making sure that they are not reversed;
3) Check the power supply complying with the specification;
4) If the supply has a current limit, set this to 350mA;
5) Make sure to install the Rhombus100 in a environment without large area conductors nearby or mounting on a conductive surface. In self-test state, do not apply any tags in functional area;
6) Try to change the installment of LCR-100 to another place to check if the trouble still exists;