vedio signal switcher
Isolated PROFIBUS repeaters, extending a 2 km (9600bps)-long two-way communication distance,rate is 0 ~ 1.5 Mbps.
E485GP is compatible with Siemens repeater 6 ES7 972-0AA01-0XA0, is the high-speed isolated PROFIBUS repeaters designed for PROFIBUS bus, applicable to all RS485 network such as the PROFIBUS network, PPI network, MPI network, MODBUS network and Free Port communication network. It can realize the signal isolation and amplification. When the RS485 communication distance is over the corresponding baud rates allowing, or nodes on the network are more than the allowed number, you should use repeaters to amplify the signal. The products have characteristics such as extending communication distance, automatically switching the flow of signals and automatically adaptation of baud rate. All their industrial-grade devices are anti-static and anti-lightning, make them work stably in the poor industrial environment.
When the number of nodes witch connected to the bus is more than 32 or of the connective cable between buses exceeds the maximum length of cable(see table below), you need to use repeaters to amplify signal.
Note 1
Baud rate | The maximum cable length of busm |
9.6 to 187.5Kbps | 1000 |
500Kbps | 200 |
1.5Mbps | 100 |
Technical details
isolated voltage: 1000 VDC (up to 3000 VDC, statement is required when ordering) communication rate: 0 ~ 1.5 Mbps automatically adaptive greatest distance: 2km (9.6 Kbps), 1500m(19.2 Kbps), 800m(187.5 Kbps), 200m(500 Kbps), 100m(1.5 Mbps) Power: 24 VDC 1W DC power supply protection of open-circuit, short-circuit and gap fault of bus 600 W built-in anti-lightning protection, ± 15KV ESD (electrostatic) protection integrated terminal and bias resistors, data sending and receiving indicator light temperature: -40 ~ +85 Dimensions: 85 × 55 × 25 (L × W × H), installation of standard rail Weight: 100 gDefinition of the bus paragraph 1 and 2s connection terminal signal
Bus paragraph 1 connection terminalleft | Bus paragraph 2 connection terminalright | ||
Signal-name | description | Signal-name | description |
A1 | Bus paragraph 1s RS485 signal negative | A2 | Bus paragraph 2s RS485 signal negative |
B1 | Bus paragraph 1s RS485 signal positive | B2 | Bus paragraph 2s RS485 signal positive |
FG | Chassis ground,connect the shielding layer of cable | FG | Chassis ground,connect the shielding layer of cable |
A1 | Bus paragraph 1s RS485 signal negative | A2 | Bus paragraph 2s RS485 signal negative |
B1 | Bus paragraph 1s RS485 signal positive | B2 | Bus paragraph 2s RS485 signal positive |
FG | Chassis ground,connect the shielding layer of cable | FG | Chassis ground,connect the shielding layer of cable |
+24V | External connect the anode of 24V DC power supply |
| |
0V | External connect the cathode of 24V DC power supply |
|
Definition of programming device PG/OP socketDB9F socketsignal
Pin number | Signal-name | description |
1 | ----- | ---- |
2 | M24V | 24Vground |
3 | RXD/TXD | Data wire BRS485 signal positive |
4 | ---- | ---- |
5 | M5V | Data reference potential5V ground |
6 | P5V | 5V power anode |
7 | P24V | 24V power anode |
8 | RXD/TXD | Data wire ARS485 signal negative |
9 | ---- | ---- |
Model:SD-485T485, fiber optic vedio signal switcher