Model | SMB-H6K/1S | |
INPUT (AC/DC) | AC .Input Voltage range | 280-600 V AC 3 phases |
DC. Input voltage range | 300-600 V DC single phases | |
Number of MPPT /Max.number | 1/3 | |
OUTPUT AC | Continuous Output Power. KW | 6000 |
Max.AC Output Current. A | 32 | |
Battery | Recommend batteries voltage.V | 168 |
CC-Constant current | 0.01-0.05C | |
CV-Constant voltage | 0.1C | |
Floating | 0.01C | |
Switching time | less than 5ms | |
General Data | Grid Voltage. A | 220-240V or adjusted to local regulation |
Grid Frequency/Range | 50/60Hz or adjusted to local regulation | |
Factor | ≥0.99999999 | |
Overload capacity | >110% alarm for 60sec; >110%~150% alarm for 10sec; >150% shutdown | |
THD(%) | less than 3% | |
Max. efficiency | 97% | |
European-Efficiency | 95.50% | |
Protection | Over voltage protection, Under voltage protection, Over frequency protection. Under frequency protection, Over current protection, AC short-circuits protection, Ground fault protection,DC Reverse polarity protection, Over load protection. | |
Dimensions(H/W/D)mm | 600/360/190 | |
Weight(kg) | 36 | |
Operating temperature. °C | -25~+50°C | |
Standby power consumption | 5W | |
Noise | ≤ 42 dB(A) | |
Topology | transformerless | |
Protection grade | IP65 | |
Cooling concept | Natural Cooling | |
Features | Graphic display | LCD |
LCD Parameter | Grid frequency-voltage; Environmental temperature, time; Statistics of output power voltage current; Inverter efficiency; Work logs for 3 years; Failure Analysis; Running State Analysis, Generated energy, Battery voltage, charge type, battery capacity, etc. | |
Interfaces: | RS485/RS232 | |
Warranty | 5 years | |
Software | SFENGINEER |