Advantage: Disjunction ability 10KA.
Technology specification 1P+N 2P
Trip time :minimal 10ms time delay
Rated Voltage :230V;50Hz 230v/400v
Rated breaking capacity :10/30v;300mA 30;300mA
Sensitivity:AC,A.
Selection grade:3
Rated breaking capability:10kA.
Rated current:6-40A 6-32A
Tripping character: C characteristic curve
Maximun connected fuse:100A gl(>10kA)
Environment capability:According the To IEC1008 standard
Case protection grade:IP40(After installation)
Electric Life : No less than 4000 times of breaking and closing
Moto Mechanical: No less than 20000 times of breaking and closing
Mechanical parameters
Installation mode: installaion at the DIN guide rail of 35mm
Terminal wiring capability: Conductor 1-25mm²
Case height:35mm(1p+N)52mm(2P)
Accesory:busway Thickness 0.8-2mm
Main character
Action function independent of the voltage of main circuit.
The neutral line breaking could make the device safer and more reliable.
Dual-function wiring terminal with strong wiring capability.
The indicator for contact state help identification of contact condition.
Different hand handle color is to indicate the rated current.
Disjunction ability went to 10kA
Wide rated currents cope to serve as general switch at home service.
Integration of three protection functions of leakage ,overload and short-circuit.
To prevent the false tripping caused bu the switching operation of electronical equipment.
earth leakage circuit breaker