Fuel Pump type electric water heater
Fuel Pump type electric water heater
Supplier Info
[China Supplier]
Contact Person : Mr. zheng jing
Tel : 86-577-62712750
Fax : 86-577-62712782
Product Detail
which the poles are below 5P ,besides , installed in computer room,vending machine,microwave cooker,fridge ,CT machine and etc.

1. Function

   1) A type leakage current protect

  2) It can protect the AC leakage, and to the lag voltage 0°,90°,135°,±DC6mA,that is to say what including the harmonic current will have leakage protection

   3) Energy conservation,environmental protection,electronic circuit module, it can save 2.5mA than the other leakage current switch , the electronic circuit solid module  which can anti-water, anti- mildew, anti- quake and etc

    4) compare with the traditional AC type leakage current circuit breaker, it is more full-scale and safer, it can prevent the accident when the insulation component is damaged and cause the earth bug

2. Technical parameter

   1) Rated current Im (A):32

   2) Rated voltage Um (V):230

   3) Rated frequency (Hz):50/60Hz

   4) Rated connected on-off capacity Im (A):500

   5) Rated limited short –circuit capacity (A):3000

   6) Rated residual operated current I n(mA)

  a. Current and voltage when they are same phase: 15 ≤ I n ≤ 30

  b. Current lag voltage 0°: 10.5≤I n≤42

  c. Current lag voltage ±90°:    7.5 ≤ I n ≤ 42

  d. Current lag voltage ±135°: 3.3 ≤ I n ≤ 42

e.0°± DC 6mA: 10.5 ≤ I n ≤ 42

3. Range of application

  1) It is installed in the Factory,Building, Residential,School,Hospital,Hotel and etc.

  2) It is installed in the Inverter Air Conditioner , Ordinary Air Conditioner , Hot-water electric water heater,Heat pump electric water heater which the poles are below 5P ,besides , installed in computer room,vending machine,microwave cooker,fridge ,CT machine and etc.

  3) If they are energy conservation products which have the harmonic ,should install the model.

4. Working condition

  1) The ambient air temperature: the upper limited value ≤+40°C, the lower limited value ≥-5°C,the average temperature ≤+35°C in 24 hours

  2) The atmospheric relative humidity is ≤50% when the ambient air temperature is +40°C, the humidity is ≤90% at the lower temperature(≤20 °C)

 3) Near the installed places, the earth magnetic field can not be more than 5 times in the any directiom