Fully Auto chemistry Analyzer High Analysis Function Real-time Display the Work Condition

 Fully Auto Medical Chemistry Analyzer

System function

Throughput: up to 450 tests/Hour (not including ISE tests)

Test Method: End point, Fixed time, Kinetic

Test Sequence: Discrete, Random access, STAT can be inserted at any time. Test sequence can be sorted by samples or items

Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.

Cuvette washing: auto wash the cuvettes through 6 segments washing pipe and continuous use them, and each cuvette wash 12 times before use it again.

Reaction detect: monitor 81 cuvettes’s reaction at the same time

Photometric process: the interval time between two consecutive photometric points are exactly the same.

Pipeline system: pressure auto released pumps and double filters to protect pumps and valves

Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts

Environmental resistance: resistant form dust and water vapor 

 Sample volume: 2μL~30μL, step by 0.1μL

Sample disc: 60 positions for primary tubes and secondary cups

Sample probe: inner and outer walls are highly polished leads carry-over < 0.1%, level detection and vertical and horizontal collision protection

Sample tube: both primary tubes and secondary cups are suitable

Reagent volume: 20μL~300μL, step by 1μL

Reagent disc: provide 80 reagent bottle positions

Reagent probe: inner and outer walls are highly polished leads carry-over < 0.1%, level detection and vertical and horizontal collision protection

Reagent bottle: particular reagent bottle without dead volume

Reagent Cooling: continuous cooling system according to the principle of peltier

Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.

Water consume: < 6L/hour

Carry over: Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted

Reaction system

Cuvette: permanent UV free glass cuvette

Reaction disc: Discal reaction disc with 81 disposable cuvettes

Reaction volume:150Μl~600μL

Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free

Temperature: 37±0.1 centigrade

Optical system

Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours

Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free

Wavelength: 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm

Absorbance range: 0~6

Calibration/QC

Calibration type: single point linear, two points linear, multi-points linear, Logit-4P, Logit-5P, Spline, Exponential 5P, Polynomial 5P, auto choose the best fittest calibration curve.

QC type: real time QC, daily QC, day to day QC

QC chart: L-J, Cumulative sum check, Twin Plot

QC rule: Customized QC rule in order to adapt different item’s requirements

Operational system

Operational system: VISTA, Windows XP, Windows2000

Memory: auto save and recover the results

Report format: Customized report format

Status Check: real time check the working status of the analyzer

Power/ Dimension

Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage

Power Consume: ≤550VA

Dimension: 980(L)X 712( W) X 1100(H)

Net weight: 160Kg