Flexible Fluoroplastic Insulation Small Diameter Coaxial Cable
Construction Specifications
Item Material Diameter (mm)
1. Inner Conductor Silver Plated Copper Clad Steel 7*0.102
2. Dielectric PTFE 1.60
3. Outer Conductor Double Silver Plated Copper Braid 2.50
4. Jacket FEP 3.00
Electrical Specifications
Capacitance (pF/m) 64
Impedance (ohm) 75
Velocity (%) 70
Maximum Operating Voltage (KV) 1.2
Maximum Work Frequency (MHz) 400
Mechanical Specifications
Minimum Bending Radius (mm) 10
Operation Temperature (°C) -55~+200
Attenuation (20°C, Sea Level)
Frequency (GHz) Attenuation (dB/m)
0.1 0.266
0.4 0.541
1.0 0.869
Note: Maximum attenuation value should be 110% of the nominal attenuation value.