Plastic(PVC) insulated control cable
Plastic(PVC) insulated control cable
Supplier Info
[China Supplier]
Contact Person : Mr. Ju Haibo
Tel : 086-510-87290666
Fax : 086-510-87290123
Product Detail
PVC control cable CE certification GB/T5023-20008 JB8734-1998 More than 20 years' experience Fast delivery

Plastic insulated control cable(contain:fire resistant,flame retardant,halogen free low smoke etc.)

KVV

Copper conductor PVC insulated PVC sheathed control cable

KVVP

Copper conductor PVC insulated PVC sheathed control cable with braided shield

KVVP2

Copper conductor PVC insulated PVC sheathed control cable with copper tape shield

KVV22

Copper conductor PVC insulated PVC sheathed control cable with steel tape armour

KVV32

Copper conductor PVC insulated PVC sheathed control cable with steel wire armour

KVVR

Copper conductor PVC insulated PVC sheathed flexible control cable with shield

KVVRP

Copper conductor PVC insulated PVC sheathed

Flexible control cable with braided shield

ZR-KVV

Copper conductor PVC insulated PVC sheathed flame retardant control cable

ZR-KVVP

Copper conductor PVC insulated PVC sheathed flame retardant control cable with braided shield

ZR-KVVP2

Copper conductor PVC insulated PVC sheathed flame retardant control cable copper tape shield

ZR-KVV22

Copper conductor PVC insulated PVC sheathed flame retardant control cable with steel tape shield

ZR-KVV32

Copper conductor PVC insulated PVC sheathed flame retardant control cable with fine steel wire armour

ZR-KVVR

Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable

ZR-KVVRP

Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with braided shield

KVVRP1

Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with spiral shield

KVVRP3

Copper conductor PVC insulated PVC sheathed flame retardant control flexible cable with PVC-Aluminum complex shield

1.  Applications

1 Rated voltage U0/U should be 450/750 V~600/1000V

U0~Valid value of the voltage between main insulated conductor and earthing (metal shield, metal sheath of environment dielectric).

U~valid value of voltage between any two phases conductor in multicourse cable or single core cable system.

When AC. System is applied, the rated voltage of cables should be at least equal to the nominal voltage of the system. When DC. System is applied; the nominal voltage of this system should not be more than the rated voltage of the system by 1.5 times.

2 The permitting long-term operating temperature of cable conductor should be

PVC insulation: 70

Chemical Sioplascable: 90

Irradiation XLPE :105~135

3 The installing temperature of cable should not be less than 0. Recommending permitted bending radius:

Non-armored cable: not less than the overall diameter f cable by 6 times

Shielded flexible cable: not less than the overall diameter of cable by 6 times