Welcome to ECVERY
125kva generator for sale ,generating 80kva ,100kva for option
125kva generator for sale ,generating 80kva ,100kva for option
Supplier Info
[China Supplier]
Contact Person : Mr. Cao Kris
Tel : 86-592-5685493
Fax : 86-592-3778097
Product Detail
125kva cummins 6BTA5.9-G2 engine 8hours base fuel tank Global warranty 1year or 1000hours CE and ISO approved OEM price

cummins genset data

Prime power125 kVA
Standby power132 kVA                                             
Rated speed1500 RPM
Output frequency50 Hz
Phase3
Rated voltage400 V
Engine model6BTA5.9-G2
Alternator modelUCI 274D
Fuel consumption of 100% load27 Litres/h
Fuel consumption of 75% load20 Litres/h
Voltage regulation rate≤±1%
Random voltage variation≤±1%
Frequency regulation rate≤±5%
Random frequency variation          ≤±0.5%

6BTA5.9-G2  cummins engine data

Engine model6BTA5.9-G2
Engine manufacturerCummins
Number of cylinders6
Cylinder arrangementVertical in-line
CycleFour stroke
AspirationTurbocharged and After water-cooled
Bore×Stroke (mm×mm)102 x 120
Displacement (Liter)5.9
Compression Ratio17.5:1
Prime power/speed (kW/RPM)106/1500
Standby power/speed (kW/RPM)116/1500
Speed governorElectrical
Cooling systemForced Water Cooling Cycle

Steady speed droop (%)

≤1%

Total lubrication system capacity(L)

16.4

Coolant capacity (engine only)(L)

9.1

Fuel consumption at 100% load (g/kWh)

211 (at 1500RPM)

Starter motor

DC24V,

Alternator

AC24V

Alternator data 

Alternator modelUCI 274D
Alternator manufacturer                     Stamford
Exciter typeSingle bearing, Brushless, Self-excited
Rated output prime power120 kVA
Rated speed1500 RPM
Rated frequency50 Hz
Phase3
Rated voltage400 V(Available with customer requirements)
Power factor0.8
Voltage adjust range≥5%
Voltage regulation NL-FL≤±1%
Insulation gradeH
Protection gradeIP23

Controller :Smartgen brand HGM6120K (standard)  

Feature:

protection: Automatic start/stop, load transfer and alarming of generator;Three channel analog inputs, may joint with Resistive-type temperature/ pressure/ fuel level sensors, Several temperature and pressure sensors can be used directly (ie. VDO, DATCON, CUMMINS), also may select “user defined” sensor via entering 8 point curves; Display of generator cumulated electric energy;Security password-protected programming levels. Several crank success conditions are optional;Power supply range is wide, accommodating to different starting battery voltage environments;All parameters use digital modulation, abandoning analog modulation using conventional electronic potentiometer, reliability and stability are increased; Built-in watch dog can never be dead halt, ensuring smooth program execution;

Parameter:

Generator Volts, Amps, Frequency, active power, apparent power , power factor, Engine Oil Pressure, battery volt, Engine speed, engine temperature, Engine Hours Run, fuel level.

Protection:

1.Low Oil Pressure     2.High voltage and low voltage      3. Volt adjuster and frequency adjuster 

4.Overspeed                5. Emergency stop          6.Fail to start           7. High Engine Temperature

General FeaturesEvery generator set is subjected to a comprehensive test program which includes 50% load, 75% load,100% load, 110% load and the checking and proving of all control and safety shut-down functions. Equipped   with   battery   charger   and   24V   high

performance maintenance-free lead-acid starting batteries and connecting with cables. Equipped with industrial silencer and flexible exhausthose.

Equipped with 8-hours operation base tank; z Equipped with CHINT MCCB circuit breaker; z Designed to Comply with ISO8528/GB2820; z Powered   by  Cummins  engine  and  coupled  withStamford alternator.

Benefits Function stability credibility, service convenience; z Low operating cost results in optional economy; z Gets the job done wherever you are;

Ease of installation, operation and maintenance.

Generator Set Options and Accessories

Generator setSilence generator set

 Trailer generator set ABB MCCB circuit breaker

Fuel system12 hour base tank(single wall)

 24 hour base tank(single wall)Dual wall base fuel tankOutside fuel tank

Exhaust systemResidential exhaust silencerAlternator PMG excitation Space heater

Low environment temperature Water heater Oil heater Battery heater

Control system AMF function ATS control cabinet Multiple generator automatic synchrorising

125kva 6BTA5.9-G2  cummins generator set

65db  @  7 meters  cannopy for option

ATS for option

Top brand !!! Marathon alternator for option  

kinds of controller for option (smartgen is chinese big brand )

CE &ISO&IAF  ,Cummins OEM  ......Certificates approved

Our promise

Pre-sales guidance:

Disaier Company professional technician responsible for users’ technical advisor question, make sure the configuration, features, optional items etc.

After-sales service:

Customers supreme, service-oriented

1 year or 1,500 running hours Quality Warranty, whichever comes first.

24 hours after-sales service telephone helpline. Within guarantee period if parts impaired, Cost offer parts (within factory standard parts) and technical.