Working pressure: 2,000psi - 15,000psi Nominal bore size: 2.1/16"to 4.1/16" kill manifold:14MPa,21MPa,35MPa,70Mpa

Choke Manifold

1. ApplicationChoke manifold is necessary device to control the well kick successfully and execute the pressure control technology on oil/gas well in the course of drilling, as it is, the device is adopted to execute new drilling-well’s technique of balance pressure, which can prevent the pollution of oil-layer, improve the speed of drilling and control blowout effectively. One end of the devicecon nects with the side flange of BOP spool. When BOP closes, it can control the finite pressure from casing by adjusting the choke valve’s opening, so balanced drilling can work under minimum pressure-difference.2. Assembly & structureChoke manifold consists of choke valve, gate valve, pipeline, fittings and pressure gauge etc.3. Working principleWhen the pressure rising in well, fluid in well can be released in utilization of the choke valve opening/closing in choke manifold to control casing pressure, which can directly blow out through gate valve as the casing pressure is quite high.4. SpecificationPressure level is divided into five levels, i.e. 2,000psi, 3,000psi, 5,000psi, 10,000psi, 15,000psi; it can be designed according to the requirement of customer.5. Operation requirement(1)All the working pressures of parts in choke manifold should be matched with the working pressure of the BOP stack used,(2)Choke manifold should be installed at the place where operator approach it conveniently, pressure test should be executed as installation, while the sealing test pressure should equal to the rated working pressure;(3)Pipeline should be so smooth and straight as possible, the corner of the pipeline should be made of 120°shaped forged steel bent pipe, which should have adequately large bore.(4)The working pressure gauge should be installed.(5) In winter, the choke manifold be able to work under a low temp condition.

Fabrication of choke manifold is according to the requirements of API spec 16C.Working pressure: 2,000psi - 15,000psiNominal bore size: 2.1/16” to 4.1/16”

Type

Working pressure

(Mpa) (psi)

Nominal diameter

(mm) (inch)

Bypass diameter

(mm) (inch)

YJX140

140Mpa (20000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

YJX105

105Mpa (15000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

YJX70C YJX70E

70Mpa (10000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

(Y)JX35

35Mpa (5000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

(Y)JX21

21Mpa (3000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

 

Kill Manifold

1.       ApplicationIn case of increase in well head pressure, the kill manifold can provide a means of pumping heavy drilling fluid into the well to balance bottom hole pressure so that well kick and blowout can be prevented. In this case, by using blow down lines connected to the kill manifold, the increasing well head pressure also can be released directly for bottom hole pressure release, or water and extinguishing agent can be injected into the well by means of the kill manifold. The check valves on the kill manifold only allow injection of kill fluid or other fluids into the well bore through themselves, but do not allow any backflow so as to perform the kill operation or other operations.2. StructureThe kill manifold consists of check valves, gate vales, pressure gauges and pipelines. The one end of the kill manifold is connected to the drilling spool and the other end is connected to the pump. The kill manifold and choke manifold are both designed to API 16C and can be used together. The kill manifold is available from 14MPa, 21MPa, 35MPa and 70MPa pressure ratings.3. Operating Requirements(1) Working pressure of all pipelines, gate valves and check valves shall be compatible with that of the BOP stack used.(2) The kill manifold is not intended to be used as common lines for pouring drilling fluid.

Type

Working pressure

(Mpa) (psi)

Nominal diameter

(mm) (inch)

Bypass diameter

(mm) (inch)

YGJX140

140Mpa (20000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

78(3-1/16),65(2-9/16),

52(2-1/6)

YGJX105

105Mpa (15000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

78(3-1/16),65(2-9/16),

52(2-1/6)

YGJX70 YGJX70A

70Mpa (10000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

YGJX35

35Mpa (5000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

YGJX21

21Mpa (3000psi)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

103(4-1/16),78(3-1/16),

65(2-9/16),52(2-1/6)

 