Product Detail
Auto egg incubator: This module type is JN 8-48, Which is auto turner egg incubator, and it can hatch 48 pcs eggs.

automatic egg incubator JN8-48,it is a newest family incubator. and capacity is 48pcs egg.

automatic egg incubator

JN8-48,48pcs egg newest family incubator.

1pcs/colour carton,2 pcs/big carton,

packing size is 52x60x53/15kgs/2set.

Function instruction:

HU, HD:

Parameter HU and HD, set by factory, is supposed not to be modified by user.

Temperature correction function: 

When measuring temperature deviates from reference temperature, temperature correction function shall be used to make the measuring value in accordance with reference temperature, temperature after correction shall be the sum of temperature before correction and correction value (correction value can be positive number, negative number or zero).

Temperature correction set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “CA” appears on screen, then push “SET” to display temperature correction setting value, push “+” or “-” again to adjust parameter.

Upper and lower limit function:

HS and LS set limits setting range of temperature control, e.g., if HS is set as +15 and LS is set as -10, then the temperature can only be set from -10 to +15, so the display value still keeps as -10 after pushing  “-” if it displays -10; the display value still keeps as +15 after pushing ““+”” if it displays +15. If setting value is beyond the setting range, then HS and LS must be changed at first

 Upper and lower limit set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “HS” or “LS” appears on screen, push “SET” to display upper or lower limit setting value, then push “+” or “-” to adjust the parameter. HS means upper limit and LS means lower limit.

Humidity alarm function:

If measuring humidity is less than AU setting value, the temperature controller sends alarm and the humidity indicating lamp flickers. The alarm can stop by pushing any button.Humidity alarm set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “AS” appears on screen, push “SET” to display humidity alarm setting value, then push “+” or  “-” again to adjust parameter.

High temperature alarm function:

If measuring temperature is higher than sum of setting temperature and AH, the temperature controller sends alarm and the display screen alternately displays H and current temperature. The alarm can stop by pushing any button.

 High temperature alarm set:

Push “SET” for 3s to enter menu display, push “+” or  “-” until code “AH” appears on screen, push “SET” to display high temperature alarm setting value, then push “+” or “-” to adjust parameter, the high temperature alarm function can be closed when AH is set as 0.

Low temperature alarm function:

If measuring temperature is lower than the result when setting temperature minus AL, the temperature controller sends alarm and the display screen alternately displays L and current temperature. The alarm can stop by pushing any button.

Low temperature alarm set:

Push “SET” for 3s to enter menu display, push “+” or “-” until code “AL” appears on screen, push “SET” to display low temperature alarm setting value, then push“+”  to adjust parameter. The low temperature alarm function can be closed when AL is set as 0.

 Menu Code Selection

Symbol

Instruction

Setting range

Factory set

Unit

HU

Heating power parameter

1-90

18

 

HD

Heat preservation power parameter

1-80

11

 

LS

Setting lower limit

-9.9~HS

30

°C

HS

Setting upper limit

LS~99.9

39.5

°C

CA

Temperature correction

-5~+5

0

°C

AS

Humidity alarm

1~99

45

%

AH

Ultrahigh temperature alarm output

0-15

1

°C

AL

Ultralow temperature alarm output

0-15

1

°C