Ads by Google
UL21002 Medical cable
Product Description:
1.Tinned,annealed,stranded or solid copper conductor.
2.TPE or XL-PE,FR-PE insulation.TPE jacketed.
3.Rated temperature: 105°C.Rated voltage: 300volts.
4.Tinned or bare copper wire spiral or braid shield
5.Passes UL VW-1&CUL FT1 vertical flame test
Applications:
Internal wiring or external inter-connection of electronic equipment (such as desk-type calculators, dictating machines, or X-ray equipment).
UL Style& CUL Type | Cores | Conductor | InsulationThickness | Nom.Dia | Shield Coverage | Jacket Thickness | OverallDimeter | ConductorResistance at 20°C | |
AWG | No/mm | mm | mm | % | mm | mm | Ω/KM | ||
UL21002CUL(Stranded) | 2C | 30 | 7/0.100 | 0.38 | 1.10 | >=65 | 0.76 | 4.40 | 381.00 |
28 | 7/0.127 | 0.38 | 1.20 | >=65 | 0.76 | 4.50 | 239.00 | ||
26 | 7/0.16 | 0.38 | 1.30 | >=65 | 0.76 | 4.60 | 150.00 | ||
24 | 11/0.16 | 0.38 | 1.40 | >=65 | 0.76 | 4.90 | 94.20 | ||
22 | 17/0.16 | 0.38 | 1.60 | >=65 | 0.76 | 5.10 | 59.40 | ||
20 | 21/0.178 | 0.38 | 1.80 | >=65 | 0.76 | 5.50 | 36.70 | ||
18 | 34/0.178 | 0.38 | 2.10 | >=65 | 0.76 | 6.10 | 23.20 | ||
16 | 26/0.25 | 0.38 | 2.40 | >=65 | 0.76 | 6.90 | 14.60 | ||
UL21002CUL (Stranded) | 3C | 30 | 7/0.100 | 0.38 | 1.10 | >=65 | 0.76 | 4.50 | 381.00 |
28 | 7/0.127 | 0.38 | 1.20 | >=65 | 0.76 | 4.70 | 239.00 | ||
26 | 7/0.16 | 0.38 | 1.30 | >=65 | 0.76 | 4.90 | 150.00 | ||
24 | 11/0.16 | 0.38 | 1.40 | >=65 | 0.76 | 5.10 | 94.20 | ||
22 | 17/0.16 | 0.38 | 1.60 | >=65 | 0.76 | 5.30 | 59.40 | ||
20 | 21/0.178 | 0.38 | 1.80 | >=65 | 0.76 | 6.00 | 36.70 | ||
18 | 34/0.178 | 0.38 | 2.10 | >=65 | 0.76 | 6.60 | 23.20 | ||
UL21002CUL (Stranded) | 4C | 30 | 7/0.100 | 0.38 | 1.10 | >=65 | 0.76 | 4.70 | 381.00 |
28 | 7/0.127 | 0.38 | 1.20 | >=65 | 0.76 | 4.90 | 239.00 | ||
26 | 7/0.16 | 0.38 | 1.30 | >=65 | 0.76 | 5.20 | 150.00 | ||
24 | 11/0.16 | 0.38 | 1.40 | >=65 | 0.76 | 5.60 | 94.20 | ||
22 | 17/0.16 | 0.38 | 1.60 | >=65 | 0.76 | 5.90 | 59.40 | ||
20 | 21/0.178 | 0.38 | 1.80 | >=65 | 0.76 | 6.40 | 36.70 | ||
UL21002CUL(Stranded) | 5C | 30 | 7/0.100 | 0.38 | 1.10 | >=65 | 0.76 | 4.90 | 381.00 |
28 | 7/0.127 | 0.38 | 1.20 | >=65 | 0.76 | 5.10 | 239.00 | ||
26 | 7/0.16 | 0.38 | 1.30 | >=65 | 0.76 | 5.20 | 150.00 | ||
24 | 11/0.16 | 0.38 | 1.40 | >=65 | 0.76 | 5.60 | 94.20 | ||
22 | 17/0.16 | 0.38 | 1.60 | >=65 | 0.76 | 6.20 | 59.40 | ||
UL21002CUL (Stranded) | 6C | 30 | 7/0.100 | 0.38 | 1.10 | >=65 | 0.76 | 5.10 | 381.00 |
28 | 7/0.127 | 0.38 | 1.20 | >=65 | 0.76 | 5.50 | 239.00 | ||
26 | 7/0.16 | 0.38 | 1.30 | >=65 | 0.76 | 5.90 | 150.00 | ||
24 | 11/0.16 | 0.38 | 1.40 | >=65 | 0.76 | 6.20 | 94.20 |
UL21002 Medical cable