PVC insulated and sheathed screened wires AVP RVP RVVP
Conductor type | Code | Nominal voltage U0/U | No. of cores | Range of cross section mm2 | Temperature range at | |
Cont. load max. | Installation/ Handling | |||||
Cooper core PVC insulated screened wire | AVP | 300/300V | 1 | 0.08-0.4 | +70°C | +5°C |
PVC insulated screened flexible wire | RVP | 300/300V | 1 2 | 0.08-2.5 0.08-1.5 | +70°C | +5°C |
PVC insulated and sheathed, screened flexible wire | RVVP | 300/300V | 1 2 3 4-24* | 0.08-2.5 0.08-1.5 0.12-1.5 0.12-0.4 | +70°C | +5°C |
*Series of core number: 4, 5, 6, 7, 10, 12, 14, 16, 19 and 24. |
Conductor
Finely stranded Copper conductor, bare
Insulation
PVC
Sheath
PVC
Screen
Cu, TC
Recommended application
Fit for AC rated voltage 300/300V electric appliances, instruments and meters, electro-equipment and automatic installations
Nominal Cross section | Conductor core | Insulation thickness | Individual wires diameter of screen
| Max. average outer diameter () | Conductor resistance at 20°C max. | Insulation resistance at 70°C max. | |
No. of individual wires/diameter | |||||||
mm2 | mm | mm | mm | mm | Ω/km | MΩ•km | |
AVP | |||||||
0.08 | 1/0.32 | 0.4 | 0.10 | 1.9 | 225.2 | 0.019 | |
0.12 | 1/0.40 | 0.4 | 0.10 | 2.0 | 144.1 | 0.015 | |
0.2 | 1/0.50 | 0.4 | 0.10 | 2.1 | 92.3 | 0.015 | |
0.3 | 1/0.60 | 0.4 | 0.10 | 2.2 | 64.1 | 0.014 | |
0.4 | 1/0.70 | 0.4 | 0.10 | 2.3 | 47.1 | 0.012 | |
RVP RVVP | |||||||
0.08 | 7/0.12 | 0.4 | 0.10 | Depending on the number of cores | 247 | 0.018 | |
0.12 | 7/0.15 | 0.4 | 0.10 | 158 | 0.016 | ||
0.2 | 12/0.15 | 0.4 | 0.10 | 92.3 | 0.013 | ||
0.3 | 16/0/.15 | 0.5 | 0.10 | 69.2 | 0.014 | ||
0.4 | 23/0.15 | 0.5 | 0.15 | 48.2 | 0.013 | ||
0.5 | 16/0.20 | 0.5 | 0.15 | 39.0 | 0.012 | ||
0.75 | 24/0.20 | 0.5 | 0.15 | 26.0 | 0.010 | ||
1.0 | 32/0.20 | 0.6 | 0.15 | 19.5 | 0.010 | ||
1.5 | 30/0.25 | 0.6 | 0.15 | 13.3 | 0.009 | ||
2.5 | 49/0.25 | 0.7 | 0.15 | 7.98 | 0.008 |
PVC insulated and sheathed screened wires AVP RVP RVVP