Anesthesia Machine tidal volume 50~1500ml frequency 4~60bpm I:E 2:1~1:8 trigger sensitivity -1.0~-0.1Kpa

Anesthesia Machine

Anesthesia Machine's 

based on ergonomics of the design, structure concise and fluent, mobile, lightweight comfortable. Microcomputer control of the ventilator imported sensors and components, and production processes to ensure that rigorous internal quality products, folding bellows breathing mechanical ventilation system so that security situation, intuitive. High-precision anesthesia evaporators to ensure that the concentration of anesthesia output accuracy. Power transmission and gas metering system to ensure the safe and reliable gas supply. The aircraft brought together a number of modern technologies, is a fine performance, functionally complete anesthesia machine.

This machine uses in respiratory control , respiratory intensive care , 8.4-inch high clear display, pressure – time wave and Velocity-time wave to monitor respiratory condition Multi-directionally;

The high-precision evaporator has the stable output concentration with pressure, temperature, and flow automatic compensation; Choose one among Enflurane, isoflurane and sevoflurane for a matching;

Main technical parameters

Part of Anesthesia Machine

Console

high-strength engineering plastic rack, light, beautiful and

corrosion resistance

Scope adult, child

Gas source O2,N2O,Air:0.3~.5MPa

flow meter O2: 0.1~10L/min 1.1~10L/min

N2O: 0.1~10L/min 1.1~10L/min

Air: 0.1~10L/min

O2,N2O linkage and nitrous oxide Truncation device

When use nitrous oxide, oxygen concentration>25%; when the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.

Rapid oxygen flow 35~75L/min

Vaporizer it has the function of pressure, temperature, and flow automatic compensation. The regulation range of evaporator concentration is 0~5vol%. Choose two among enflurane, isoflurane and sevoflurane for a matching according to the demands of customer. We also prepare original imported Penlon and Drager vaporizers for choosing.

Low oxygen pressure alarm

it will be alarmed when the oxygen pressure < 0.2MPa

Respiratory circuit

work mode all close. semi-close. semi-open

APL 0.5~7KPa

Bellows breathing

adults and child bellows tidal volume range:0~1500ml

child bellows tidal volume range:0~300ml

adults,children bellows,children loop are arbitrary choice for users .

Part of Ventilator

Display mode 8.4-inch high clear display

Ventilation mode IPPV SIPPV SIMV PEEP MANU SIGH

Ventilation parameters

tidal volume 50~1500ml

frequency 4~60bpm

I:E 2:1~1:8

trigger sensitivity -1.0~-0.1Kpa

PEEP 0~2.0Kpa

pressure control 1~6Kpa

SIGH 1.5 breath times

breath pause 0~50%

Ventilation monitoring parameters

tidal volume. ventilation. IPPV ratio. breath /expiratory ratio. peak pressure . pressure – time wave. velocity-time wave. total respiratory rate. airway pressure wave. PEEP. breath pressure trigger. breath pause.

Monitoring oxygen concentration 21%~100%

Security Alert System

Oxygen Concentration alarm

upper limit setting range 50%~100%

low limit setting range 15%~50%

Airway pressure alarm

upper limit setting range 1~6Kpa

low limit setting range 0.4~2Kpa

Alarm minute ventilation

upper limit setting range 3.0~30L/min

low limit setting range 1~10L/min

Asphyxia alarm

the machine will give sound and light alarm if there is no

tidal volume input in 15s

Power failure alarm

Power AC 220V±10% 50Hz±1Hz

UPS. Battery. (choose and match)

Manipulators (choose and match)

Multi-function ICU Anesthesia Machine

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.