MA2000B2 ventilator portable
MA2000B2 ventilator portable
Supplier Info
[China Supplier]
Contact Person : Ms. Yi Nancy
Tel : 0086-20-39160381
Fax : 0086-20-39154381
Product Detail
1,MA2000B2 ventilator portable 2. High-definition 8.4" TFT color LCD screen display. 3. IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

Ventilator:

1. Display mode                           High-definition 8.4” TFT color LCD screen display

2. Ventilation  mode                    IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

3. Ventilation parameters            Tidal volume        50~1500 ml

Rate                    2~99 bpm

SIMV rate            2~20 bpm

I:E                       2:1~1:8

Inspiratory trigger pressure            -1.0~2.0kPa

PEEP                                                0~2.0 kPa

Pressure range                                1.0~6.0 kPa

SIGH                                                1.5 times the inspiratory time

Inspiratory platform                         0~50%

4. Parameters for ventilation monitoring     tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform

5. Monitoring of oxygen concentration      21%~100%

6. Security Alarm System

Oxygen Concentration alarm      upper limit setting range   50%~100%

                                                   low limit setting range       15%~50%

Airway pressure alarm                upper limit setting range   1.0~6.0 kPa

                                                   low limit setting range       0.4~2.0 kPa

Per-minute ventilation volume alarm        upper limit setting range   3.0~30L/min

                                                                 low limit setting range       1.0~10L/min

Sustained high-pressure alarm       it will give alarm when stress have consistently

                                                       been higher than 2.5 kPa

Suffocation alarm         it will give sound and light alarm if there is no tidal volume input for 15  seconds

Power alarm

6. Power                          AC 220V±10%     50Hz±1Hz

                                        UPS, Storage battery

7. Mechanical Arms 

8. End-expiratory CO2 monitoring    (choose and match)

 