Welcome to ECVERY
All Kinds of IV Sets Infusion Pump IP300
All Kinds of IV Sets Infusion Pump IP300
Supplier Info
[China Supplier]
Contact Person : Mr. Du Tim
Tel : 0086-010-68813220
Fax :
Product Detail
High accuracy infusion pump Available for all kinds of IV sets Can used for neonatal Flow rate from 1ml/h to 1300ml/h CE,ISO

Infusion Pump IP300

High accuracy infusion pumpAvailable for all kinds of IV setsCan used for neonatalFlow rate from 1ml/h to 1300ml/hCE,ISO

Specifications

1. Patient type: Adult, pediatric and neonatal

2. Driven mode: Electrical motor driving

3. Applicable for all IV sets

4. Flow rate: 1mL/h~1300mL/h

5. Preset volume range: 1mL~9999mL

6. Accumulated infusion volume display range: 1mL~9999mL

7. KVO (keep vein open):

     1mL/h ≤flow rate ≤5mL/h, KVO rate is OFF

     5mL/h <flow rate <50mL/h, KVO rate is 1mL/h

     50mL/h ≤flow rate <300mL/h, KVO rate is 3mL/h

     300mL/h ≤flow rate ≤1300mL/h, KVO rate is 5mL/h

8. Flow rate accuracy:

     ±5% (specified IV set)

     ±10% after calibration (ordinary IV set)

9. Bolus rate: Five patterns: 

     600mL/h, 700mL/h, 800mL/h, 900mL/h, 1000mL/h

10. Air sensor sensitivity: ≥0.015mL

11. Occlusion detector sensitivity: Adjustable in 5 levels

       0.04MPa ±30%

       0.06MPa ±30%

       0.09MPa ±30%

       0.12MPa ±30%

       0.15MPa ±30%

12. Alarms: Internal fault, Low battery voltage, AC failure, Door open, 

Occlusion, Air in line, Empty, Heat malfunction, Interrruption of the AC power supply

13. Alarm volume: ≥65dB (A)

14. Pump running noise: ≤50dB (A)

Power Supply & Battery

Inner battery: Ni-MH 9.6V AA 1500mAh, Operating ≥4 hours after full charge

Power source: AC 100~240V, 50/60Hz;       DC 15V

Power consumption: ≤15VA

Classification & Safety

Classification: Class I; Internal power supply; type BF; IPX1

Electric security: IEC 60601-1

Security: IEC 60601-2-24

EMC: IEC 60601-1-2

Storage & Operation Condition

Storage:

Temperature: -20~55°c

Relative humidity: ≤93%

Atmospheric pressure: 50KPa~106KPa

No exposed to corrosive gases, stored in well ventilated room

Operation:

Temperature: 5~40°c

Relative humidity: 20~90%

Atmospheric pressure: 70KPa~106KPa

Altitude: 4000m below

Dimension & Weight

Dimension: H245xD180xW170mm

Weight: ≤3kg

Accessories & Document

Power calbe

User Manual

OptionalHeating function

Trolley

All Kinds of IV Sets Infusion Pump IP300

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.