10.4" color TFT LCD screen with maximum 7-waveform display CE approved
10.4" color TFT LCD screen with maximum 7-waveform display CE approved
Supplier Info
[China Supplier]
Contact Person : Mr. cheng ethan
Tel : 86-532-83877279
Fax : 86-532-83877279
Product Detail
Patient Monitor 1.10.4'screen 2.ECG,SPO2,NIBP,2-TEMP,PR,RESP 3.Option:2-IBP,ETCO2,thermal printer 5.Rechargeable battery

Patient Monitor: Model#LDM-G3F

Description:1.Displayer: 10.4" color TFT LCD screen with maximum 7-waveform display. 2.Battery: Rechargeable high-energy built-in battery3. Advanced streamline outline design, portable, compact, lightweightc4. Operating menu with multi-language interface selection:    English, Spanish, Portuguese, Chinese, French, Arabic, Russian, etc5. Easy operation with user friendly menu structure design and rotary dial 6. Against electrosurgical interference and defibrillation and no need to     disconnect the monitor from the patient in process of defibrillating.7. WAN communication function to network with central monitoring system      and make long-distance monitoring, diagnosis, maintenance and      software upgrade possible8.Optional built-in wireless networking function 9.Support external printer to record graph and trend10. Intelligent audio and visual comprehensive alarm11. In-hospital applications include emergency pre-and post-operative care,       ambulatory surgery, intermediate care/step down units, labor and delivery,        and hospital-based special procedure areas.12.Suitable for use in physicians’offices, clinics, outpatient surgical centers,     extended care facilities and other patient care areas, which of require affordable monitoring

Standard configuration:ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.

 

Optional configuration:Wireless connection, Recorder

√-- Temperature (surface and rectal)Measurement range: 25.0 – 45.0  C  Accuracy: +/- 0.1 C  Resolution: 0.1  C  response time: =< 3 min.  √ ---ECG :Input:  5 wires ECG cable Lead section: I,II,III/ aVR, aVL, aVF/ V Gain ( mm/mV ) : 1/4 , 1/2 , 1 , 2 ,4Frequency response :                       Diagnosis 0.05 - 100Hz                            Monitor 0.5 - 40 Hz                            Surgery 1.0 - 25 Hz Sweep speed(mm/sec): 12.5, 25, 50 Heart rate range: 30-254 BPMHeart rate accuracy: +/- 1 % ST segment deviation analysis: -0.8-+0.8mV ST accuracy: +/-0.02mv  √ ---Respiration Rate:( RALL impedance and nasal cavity)Measurement range: 0 - 120 BPM(adult )Accuracy: +/-1 BPM or 5 %Resolution: 1 BPM√---Power requirements :Input: 98 - 260 V AC, 50/60Hz Consumption: =< 80VA  √---Environment :                         Operation   StorageTemperature 0.5 - 40 C  -20 - 50 C Relative humidity =< 80%  √----Pulse Rate:SPO2 measurement range: 0 - 100 % Resolution: 1 %Pulse measurement range: 30- 254BPM Accuracy: +/- 2 %Resolution: 1 BPM√----NIBP (Non-invasive blood pressure)  Measurement type : adult, pediatric, neonatal Measurement range: Systolic 4.0 - 37.0 kPa                                        Diastolic 1.3 - 33.0 kPa                                        Mean 2.6 - 35.0 kPa Accuracy : +/- 0.4 kPa or 5 %Resolution: 0.1 kPaProtection: over pressure√----CO2 (side stream type)Measurement range:0-10 % (ins CO2 and et CO2)Accuracy:+/- 2 mm Hg (<  5 % Measurement value)                              10 % (>  5 % Measurement value)Response time: 180 Ms =< 90%Safety standard:  IEC 60601-1  Quality System : ISO13485: 2003

10.4" color TFT LCD screen with maximum 7-waveform display CE approved