Product Detail
9000C Monophase Defi-monitor 1.lower weight 2. novel outline 3. easy operate 4.advanced technology

 9000C Monophase Defi-monitor

Physical characteristics:

Main unit: Portable

Dimensions:L320xW205xH410

Weight:9.8kg

Technical specifications    

DEFIBRILLATOR.

(1)Defibrillator typeManual, Synchronized, Asynchronized,    

(2)Out put waveformMonophasic technology                                                                             

(3)Energy accuracy∠+1% 

    (4)  Energy selection0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)

(5)Charging time    Maximum 8 seconds to 360 Joules

    (6)  Standard Adult/Pediatric Paddles   Reusable extermal adult paddles(pediatric paddles integrated)             

.Power requirements.

(a)AC Power supply110V, 60 Hz /220V,50 Hz   

    (b) Vehicle Voltage             DC 12V

Internal Battery Backup

(1)Battery type    Rechargeable lead-acid battery

(2)Charging time    Time-Minimum of 4 hours for full charging     

    (3)Battery charging      During AC Power Supply operation of the device.

(4) Charging /Low Battery Indication      Red LED                 

(5) Battery Capacity        100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

Display

-LED Dimensions7’diagonal {155mm*88mm}

-TypeHigh resolution true-color graphic LED

-Resolution480X234

ECG

ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6, GND S-T segment analysis: -2.0~2.0mv Arrhythmia analysis: yes Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation 

Respiration

Measurement method: Thoracic impedance 

NIBP

Working mode: Manual/Automatic/stat(5 minutes) Method: Automatic oscillation Cuff type: standard Adult; optional Pediatric/Neonatal 

Temperature 

Measurement range 20~45°C 

Resolution 0.1°C

Pulse Oximetry(spO2) 

Display :spo2 value, pulse histogram, waveform, Pulse

Range: 0~99%for adult, pediatric and neonatal patients

Probe :standard adult finger clip

optional pediatric Y-type clip and neonatal wrap

Pulse range Pulse range: 0-255bpm 

Standard parameter & configuration

 ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR