Welcome to ECVERY
PMAC901 single phase Din rail energy meter
PMAC901 single phase Din rail energy meter
Supplier Info
[China Supplier]
Contact Person : Mr. Zhou Jackey
Tel : 86-756-3629673,3629699
Fax : 86-756-3629600,3629700 Address: No.15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong Zip: 519085 Country/Region: China (Mainland) Province/State: Guangdong
Product Detail
CE and KEMA certificated single phase Din rail energy meter

  PMAC901 single phase Din rail energy meter

  

Feature

•Suit for 220V AC low voltage system •6 +1 digits LCD display (999999.9 kWh)•kWh accuracy class 0.5S•LED indicates pulse, reverse energy•3 keys for programming•CT programmable, pulse output•35mm DIN rail installing, standard DIN ED5002•High temperature resistant materials•Spring type buckle, easy to install•Standard: IEC62053-21/ 22/23, CE, KEMA Basic Function•Measure and display kWh value•One RS485 communication•Support Modbus-RTU•Other real time data via RS485: V, I, P, Q, S, PF, F Optional Function•Multi-tariff•Reactive energy measuring•Demand analysis 

Technical Specification

 

Rated current

10(40)A, 10(60)A, 20(100)A or 5A/ CT

Rated voltage

AC 220Vph-N, 50Hz (optional 120V, 60Hz)

Input consumption

<2VA

Overload

115% of rated

Connection mode

PMAC901: 1-phase 2-wire

PMAC903: 3-phase 4-wire

Power supply

Self supply, 220VAC, 50-60Hz

Communication

RS485 serial, Modbus-RTU

Baud rate: 4800 or 9600bps

Address: 1~247

Environment

Operating temperature: -20°C~ +55 °C

Storage temperature: -20°C~ +55 °C

Humidity: 5%~95% non-condensing

Pulse output

1 or 2 channels,

Pulse width

90ms

Pulse constant

PMAC901:

Rated 10(40)A,10(60)A, 20(100)A: 1000imp/ kWh

Rated 5A/ CT: 1 pulse=(1÷1000 × PT × CT) kWh

PMAC903:

Rated 10(40)A, 10(60)A: 400imp/ kWh

Rated 20(100)A: 200imp/ kWh

Rated 5A/ CT: 1 pulse=(1÷3600 × PT × CT) kWh

Standard (EMC)

Electrostatic discharge immunity test

IEC 61000-4-2,Level 4

Radiated immunity test        

IEC 61000-4-3,Level 3

Electrical fast transient/burst immunity test    

IEC 61000-4-4,Level 4

Surge immunity test (1, 2/50μs~8/20μs)    

IEC 61000-4-5,Level 4

Conducted emissions             EN 55022,Class B

Radiated emissions               EN 55022,Class B

Parameter

Accuracy

Resolution

Measuring Range

PMAC901

PMAC903

 

Communication data

Voltage

0.2%

0.2%

0.01V

198V~242V (L-N)

Current

0.2%

0.2%

0.001A

0.5~4995A

Active power

0.5%

0.5%

0.1W

0~1MW

Reactive power

No

1.0%

0.1Var

0~1Mvar

Apparent power

0.5%

0.5%

0.1VA

0~1MvA

Power factor

No

0.5%

0.001

-1.000~+1.000

Frequency

No

0.01

0.01Hz

45Hz~65Hz

 

Display data

Active energy

Class 0.5S

Class 0.5S

0.1kWh

0~999999.9 kWh

Reactive energy

No

Class 2

0.1kVarh

0~999999.9 kvarh

Order Information

PMAC901  (1)-(2) - (3)-(4)

PMAC903  (1)-(2) - (3)-(4)

(1) Communication Port

C    One RS485 COM

 

(2)Optional Accuracy

1     Active energy class 1

0.5  Active energy class 0.5S

 

(3) Rated (Max.) Current 

40   10(40)A

60    10(60)A

100  20(100)A

5      5A. (When In>100A,meter connect via external CT)

 

(4) Auxiliary Function

F TOU ( Time-of-Use)

Q Reactive energy measuring (only available for PMAC903)

D Demand analysis (only available for PMAC903)

Dimension

PMAC901

PMAC903

PMAC901 single phase Din rail energy meter

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.