Welcome to ECVERY
Single-zone aerosol fire extinguishing control panel
Single-zone aerosol fire extinguishing control panel
Supplier Info
[China Supplier]
Contact Person : Mr. Yan Frank
Tel : 86-29-88332970
Fax : 86-29-88332680
Product Detail
Single-zone aerosol fire extinguishing control panel is designed in accordance with practical requirements of engineering.

General Description

Single-zone aerosol fire extinguishing control panel is aerosol fire-extinguishing control equipment designed in accordance with practical requirements of engineering. Single-zone fire extinguishing control panel is the implementing part used to drive aerosol fire extinguishing system works with the detector to combine a complete aerosol fire control system, to complete the auto control of aerosols or other fire extinguishing gases, and achieve the purpose of release fire extinguishing spray. To avoid the mis-discharge and improve reliability of the system, the emergency start/stop can be manually activated from extinguishing device or control panel emergency start/stop button.

Aerosol fire extinguishing control panel can add blow light, emergency start / stop buttons, can control the linkage equipment independently. Aerosol fire control panel has the inspection and alarm function of the external circuit breaker, and has a standby two-way configuration output.

Key Features

The control panel has a LCD display. All the operations are using the menu display. The entire process has guidance.

The control panel monitors the status of all the lines and will automatically record the latest fire happened, failure and system cases, which is easy to check and can save up to 999 cases.

The control panel designed modularization and with stable and reliable function.

The control panel can easily access to the intelligent system of the building by the module, to become a building sub-systems.

Technical Specification

AC power: 220VAC, 50Hz, 0.5A 

Wire: min 1.5 mm2

Standby power supply, Automatic charging voltage and current: 30V, 1A

Battery capacity: 4AH

Input circuitry:

-Detector circuitry connect way: two-way configuration

-Normal working voltage: 24VDC

-Alarm current consumption: 40mA

- Static detector current consumption: 2mA

Output circuitry:

-Maximum allowable line pressure drop: 2VDC

-Normal working voltage: 24VDC

-Total supply current of all peripheral: 2.2A

-Maximum current per line (except the Valve drive circuit): 0.6A

- Valve drive Relay Contact capacity: 28V 5A

-System can provide the valve drive current up to 2A. If need the valve drive more than 2A, can add more power supply.

Power supply:

Non-resettable power supply, resettable power supply and the entire output total below 3A

Dimension:

408mm×120mm×408mm (length*width*thickness)