FEATURES /FUNCTIONS
Abnormal Detection: It can automatically record the strong magnetic field disturbance and abnormal conditions.
Leakage Protection: Valve will stop automatically in case of abnormal flow increase.
Valve management: The valve will be regularly actuated once to avoid the abnormal valve open/close due to the fouling accumulated caused by no operation for a long time.
Two-way data transmission: Two-way data transmission between the management system and the meters by IC card to get the operation status of the meters.
One-card multi-meter: One card can be used in more than one meter.
Universal card: A universal card is compatible with water, energy and gas meter.
Two installation modes: Integrated or split (between base meter and IC card control part).
Communication type: Between base meter and IC card control part or other collect port is done by RS485/M_bus/PLC/RF.
TECHNICAL DATA
Production type: G1.6/G2.5/G4.0
Accuracy: B
Max. working pressure: 50KPa
Pressure difference: ≤250Pa
Pulse collecting mode: Dual-pulse collection
Power supply: 3 alkaline batteries (AA type) or M_bus supply
Operation condition:
Ambient temperature: 0-40
Ambient relative humidity:≤93%
Standard: EN1359-2006
OIML R31-1995