2011 Portable finger pulse oximeter
2011 Portable finger pulse oximeter
Supplier Info
[China Supplier]
Contact Person : Ms. Sun WenKe
Tel : 86-010-82621230
Fax : 86-010-82621230
Product Detail
finger pulse oximeter 3 65K Color OLED display SPO2 measuring range:35-99% Pulse Ratio:30-250BPM Rechargeable Li batter

 Finger Pulse Oximeter

Major Features1> Integrated with SpO2 probe and processing display module/Small in volume,light in weight and convenient in carrying2> Operation of the product is simple ,low power consumption/Operation menu for the function setting3> SpO2 value display/Pulse rate value display, bar graph display/Pulse waveform display4> The display mode can be changed/Screen brightness can be changed/A pulse rate sound indication5> With measured data overruns limits and low-voltage alarm function, the upper/down alarm range is adjustable,Battery capacity indication,Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage,   and with alarm function 6> With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers,Real-time data can be transmitted to computers7> Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe8> Wireless communication(CMS50EW) / RF Wireless communication function(Option)(Only applied for Ver6.6R or above) Connected with an external oximeter probe(Option)(CMS50EW, only applied for Ver6.6R or above of CMS50E)

Main performanceDisplay Mode: 1.3" 65K Color OLED displayScreen Resolution: 128*96SpO2 Measuring Range: 0%~100%, (the resolution is 1%).Accuracy: 70%~100%: ±2% ,Below 70% unspecified.PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)Accuracy: ±2bpm or ±2% (select larger)Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.Power Consumption: less than 100mAVoltage: DC 3.6V~4.2VPower Supply: Voltage 3.7 rechargeable lithium battery × 1  Battery Working Hour: 20 hoursBattery working life: Charge and discharge no less than 500 times.Safety Type: Interior Battery, BF Type

2011 Portable finger pulse oximeter

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.