There is always enough air available for an air to water heat pump.
SERO Heat Pumps are euuipped with defrosting systems for the safe operation at putside temperatures to -16°C. SERO offers split systems with heat pumps installed indoor. There are no restrictions for the installation as non-flammable safety refrigerants are eigher indoor or outdoor installation.
MODEL | Perform-ance at | Heating Capacity | Power | Cop | Supply power | Auxiliary heater | Compre-ssor | Heat exchanger | Water tank | Flow Tempe-rature | Weight | Sound level | ||
SS |
| KW | KW |
| V/Ph/Hz | KW |
|
| L (option) | °C | Kg | Indoor / outdoor dB(A) | ||
12 | A7/W35 | 12.9 | 3.0 | 4.2 | 400/3/50 | 3/6/9 | Scroll(1) | Fin/PBHE | 260 | 55 | 138 | 45/51 | ||
A2/W35 | 11.2 | 2.9 | 3.8 | |||||||||||
A2/W50 | 10.3 | 4.2 | 2.4 | |||||||||||
A10/W35 | 8.3 | 3.1 | 2.6 | |||||||||||
16 | A7/W35 | 16.0 | 3.7 | 4.3 | 400/3/50 | 3/6/9 | Scroll(1) | Fin/PBHE | 300 | 55 | 143 | 48/53 | ||
A2/W35 | 13.6 | 3.6 | 3.7 | |||||||||||
A2/W50 | 11.5 | 4.8 | 2.4 | |||||||||||
A10/W35 | 9.8 | 4.0 | 2.5 | |||||||||||
20 | A7/W35 | 20.2 | 4.7 | 4.3 | 400/3/50 | 3/6/9 | Scroll(2) | Fin/PBHE | 300 | 55 | 178 | 42/60 Compre-ssor outside | ||
A2/W35 | 17.0 | 4.6 | 3.7 | |||||||||||
A2/W50 | 15.6 | 6.8 | 2.2 | |||||||||||
A10/W35 | 11.6 | 4.6 | 2.5 | |||||||||||
25 | A7/W35 | 27.0 | 6.6 | 4.1 | 400/3/50 | 3/6/9 | Scroll(2) | Fin/PBHE | 360 | 55 | 185 | 42/62 Compre-ssor outside | ||
A2/W35 | 22.4 | 6.2 | 3.6 | |||||||||||
A2/W50 | 21.4 | 9.2 | 2.3 | |||||||||||
A10/W35 | 15.6 | 6.3 | 2.5 | |||||||||||
Testing:EN 14511 | Sound level:ISO 9614 & Eurovent 8/1 |
* Get more details please contact our Website or Company.
Air Source Heat Pump Heater 12~25kW (split type)