E62... room thermostat for underfloor heating
2011 E series
Programming heating thermostat with LCD screen,which has manual mode and clock-controlled programme mode.The thermostat is recommended for the control of electric heating device or on/off valve actuator in hydronic underfloor heating.
This kind thermostat has 24-event in one day and weekly programming.
Parameter: Voltage:220V/230VPower comsuption:2WSetting range:10~55celsius(can adjust to 5-90celsius)External limitation:5...60celsius(factor seting 35celsius)Switch differential:0.5-10celsius adjustablefactory setting±1 celsiusAmbient temperature:-5~50 celsiusProtective houseing:IP20 Housing material: anti-flammable PC
Sensor: NTC
Scope Of Control Application:
Control of warm-water(floor) heating systems and direct electric heating system
Control of electrically operated valve and electric-thermal actuator
Control of water pump
Control of wall mounting boiler
Sensor Failure
E0:Built-in sensor short-circuited or disconnected.E1:Exernal sensor short-circuited or disconnected.When shows E0/E1 error,thermostat must be checked till the error is eliminated.
Selection Table:
Model | Current | Application |
E62.113 | 3A | Built-in&floor sensor,floor limit sensor |
E62.123 | 3A | Built-in&floor sensor,floor limit sensor,a potential-free output |
E62.116 | 16A | Built-in&floor sensor,floor limit sensor,Cable heating |
2012 Newest temperatuer thermostat E62