qinming 2312s/m implantable pacemaker
qinming 2312s/m implantable pacemaker
Supplier Info
[China Supplier]
Contact Person : Mr. Guo Daniel
Tel : 86-10-80120615
Fax :
Product Detail
Implantable pacemaker

QINMING 2312 M/S VVI (SSI) ADVANTAGES

 

n           Thickness 6mm , weight 20.8g.

n           Inhibiting current 3.5μA, nominal service time more than 10 years.

n           9 exact programmer parameters meet the requirement of the patients perfectly;

n           The exact pulse threshold, P/R amplitude test and lead impedance measurement; 

n           The function of events count,which is helpfull to analysis and diagnoses the state of pacemaker and situation of patient;

n           Has the protection function of both runaway and crystal oscillatoer stop.

n           Complete system self-chek and correction ensure the stability of the pacemaker;

n          Programming and telemetry do not waste the energy of pacemaker battery, and prolong the longevities of pacemaker.

Qinming2312M/S  Implantable Pacemaker Specifications     

Parameters

Qinmin2312M

Qinmin2312S

Pacing Mode

SSI(VVI),SST,SOO

Basic Rate

30---(1)---60---100---(10)---160ppm

Magnet Rate

90 ppm

Upper Rate

180 ppm

Pulse Amplitude

0.1---(0.1)--- 3.8 ---(0.1)---8.1 V

Pulse Width

0.06…(0.06)…0.30,0.37…(0.06)… 0.85,0.92 …(0.06…)1.46,1.53,1.59 ms

Sensitivity

0.5---(0.5)---2.5---10 mV

Refractory Period

200---(25)---325---500 ms

Hysteresis

0---(-50)---(-350) ms

Polarity Pace

Unipolar/bipolar

Polarity Sense

Unipolar/bipolar

Disturbed Pulse Rate

Basic Rate

ERT Indication

Basic Rate decrease11%; 2.Magnet Rate decrease11%;

3. Programmer shows ERT

Battery

WG9085,1.0Ah,2.8V

Current

100% inhibited3.5μA;Standard Parameter 100% Pacing current9.2μA

Expected Service Time

122months(Standard parameter 100% pacing)

Connector

IS-1

Measurement/Weight

48.5×41×6 mm/20.8 g

X-ray Identification

QM13

Additional Functions

Interrogate: model, serial number, connector type, patient identifiers, implanted date, the latest programming date;Test battery voltagePacing event counterSensing event counterEMI event counterThreshold Test(with 0.1V resolution)P/R Amplitude TestLead impedance TestInterrogate: model, serial number, connector type, patient identifiers, implanted date, the latest programming date;Test battery voltagePacing event counterSensing event counterEMI event counter

Note: 1.Underline parameter is Factory setting;

2. Sensitivity Test Wave is 2/13 triangle wave(International Standard wave);

3. Expected service time with formula:

Expected service time(year)=Battery available energy(Ah)×106/pacing current(μA)/24/365

qinming 2312s/m implantable pacemaker