AFTERCOOLER TECHNICAL SPECIFICATIONS
Compressed air is hot and saturated with moisture upon leaving the air-compressor. Moisture in the compressed air-supply will corrode working parts, shortening their life span and resulting in repair and replacement down time.
FUNCTIONSWater-cooled after-coolers perform two essential functions. They rapidly reduce temperature of the discharged air from the compressor to a safe operating range. Substantial amount of the entrained moisture will be removed.
FEATURESThe unique system whereby water passes through the copper-nickel tubing and air-flows in the opposite direction through baffled plate inside the hot galvanized shell casing ensures trouble free operation of after-coolers. Each after-cooler is furnished with correct number square inches of zinc anode to minimize galvanic corrosion.
The after-coolers are fitted with an efficient centrifugal moisture separator that comes with 75 micron filter.
We designs after-cooler of different capacities to meet clients' specific requirement. We can also offer air-cooled after-cooler, which are wither driven by electric motor (explosion proof) or compressed air
Model No:SSCE-AC-4 Air Capacity:1400cfm Air Inlet Temperature: 80 deg.C Air Outlet Temperature:38 deg.C Entering Cooling water: 28 deg.C Cooling water quantity:30gpm Safe Working Pressure:10bar (air)/10bar (cooling water) Dimension:1.96 x 0.7 x 1.3m (H) Weight:550kg Inlet Manifold:2 ports x 2" c/w ball-valves Outlet Manifold:4 ports x 1-1/2" ball-valves and 3 ports x 1" c/w ball-valves Standard Accessories: Pressure Gauge, Safety relief valve, Temperature gauge, Moisture-separator with drain-valve, Inlet-water filter and Drain-hose (50ft)
Aftercooler