DZIJ-100/1-DJ-1 Railway locomotive wheels off hoop equipments
DZIJ-100/1-DJ-1 Railway locomotive wheels off hoop equipments
Supplier Info
[China Supplier]
Contact Person : Mr. Huang Jason
Tel : 0086-731-22461338
Fax : 0086-731-22462168
Product Detail
Wheel bands and cogs of diesel and electromotive cars of all kinds including S8 express locomotive for the purpose of quick load

Complete set of intermediate frequency induction heating equipments for wheel pair push-out de-banding of train locomotive

Complete set of intermediate frequency induction equipments for wheel pair push-out de-banding of train locomotive, a patented product of our company, offers a variety of monotype, bi-type, tertiary-type and quadruple-type as well as single and double-band for option, capable of performing heating treatment to solid wheels,wheel bands and cogs of diesel and electromotive cars of all kinds including S8 express locomotive for the purpose of quick loading.

Features : Hydraulic push-out wheels are designed to realize a more convenient and efficient lifting with high degree of automation (self-acting de-banding≤6m/piece;banding≤11m/piece, automatic constant temperature) and accuracy (measuring temperature is the actual temperature of work-pieces with accuracy of temperature control within±2°C) as well as multi-functions geared to wheel bands of all kinds of diesel, electromotive and express locomotives.

Scope of set-forming :frequency conversion mainframe (including devices for temperature measurement and PID closed-loop temperature control), combined sensors, push-out mechanism, furnace mantle, cooling water tank as well as hydraulic pressure vertical tank.

DZIJ Series Multi-functional Intermediate Frequency Wheel Pair Heating Equipments

TypeEquipment RangeRemarks
DZIJ—100/1—DJ—1

One KGPS-100-1 Frequency Conversion MainframeOne RFMO.75-1000-1S Electric CondenserOne No-core Induction HeaterTwo Hydro-cooling Cables

With Constant Temperature System and PID Temperature Measurement(variable with Hydro-coolingand Push-out Hydraulic Furnace Block System)

DZIJ—160/1—DJ—2

One KGPS-160-1 Frequency Conversion MainframeOne RFMO.75-1200-1S Electric CondenserOne No-core Induction HeaterTwo Hydro-cooling Cables

With Constant Temperature System and PID Temperature Measurement(variable with Hydro-coolingand Push-out Hydraulic Furnace Block System)

DZIJ—150/1—ZJ—1

One KGPS-150-1 Frequency Conversion MainframeOne RFMO.75-1200-1S Electric CondenserOne set of Multi-functional Intermediate Induction Heater

With Constant Temperature System and PID Temperature Measurement(variable with Hydro-coolingand Push-out Hydraulic Furnace Block System)

DZIJ—200/1—ZJ—2

One KGPS-200-1 Frequency Conversion MainframeOne RFMO.75-1500-1S Electric CondenserOne set of Multi-functional Intermediate Induction HeaterOne set of Push-out Hydraulic Furnace BlockOne set of Hydro-cooling System

With Constant Temperature System and PID Temperature Measurement,one set of Hydraulic Pressure System,one set of Hydro-cooling System,including: water tank, water pump, thermal converter and ion exchanger

DZIJ—100/1—NJ—1

One KGPS-100-1 Frequency Conversion MainframeOne RFMO.75-1000-1S Electric CondenserOne No-core Induction HeaterTow Hydro-cooling Cables

With Constant Temperature System and PID Temperature Measurement(variable with Hydro-coolingand Push-out Hydraulic Furnace Block System)

DZIJ—160/1—NJ—2One KGPS-160-1 Frequency Conversion MainframeOne RFMO.75-1200-1S Electric CondenserOne No-core Induction HeaterTwo Hydro-cooling Cables

With Constant Temperature System and PID Temperature Measurement(variable with Hydro-coolingand Push-out Hydraulic Furnace Block System)

DZIJ—100/1—DNJ—1

One KGPS-100-1 Frequency Conversion MainframeOne RFMO.75-1000-1S Electric CondenserTwo sets of Multi-functional Intermediate Induction HeaterOne set of Push-out Hydraulic Furnace BlockOne set of Hydro-cooling System

With Constant Temperature System and PID Temperature Measurement,one set of Hydraulic Pressure System,one set of Hydro-cooling System,including: water tank, water pump,thermal converter and ion exchanger

DZIJ—160/1—DNJ—2

One KGPS-160-1 Frequency Conversion MainframeOne RFMO.75-1200-1S Electric CondenserTwo sets of Multi-functional Intermediate Induction HeaterOne set of Push-out Hydraulic Furnace BlockOne set of Hydro-cooling System

With Constant Temperature System and PID Temperature Measurement,one set of Hydraulic Pressure System,one set of Hydro-cooling System,including: water tank, water pump,thermal converter and ion exchanger

DZIJ—160/1—DNnJ—2

One KGPS-160-1 Frequency Conversion MainframeOne RFMO.75-1200-1S Electric CondenserThree sets of Multi-functional Intermediate Induction HeaterOne set of Push-out Hydraulic Furnace BlockOne set of Hydro-cooling System

With Constant Temperature System and PID Temperature Measurement,one set of Hydraulic Pressure System,one set of Hydro-cooling System,including: water tank, water pump,thermal converter and ion exchanger