Product Detail
1.Rated capacity:0.5~20t 2.XBA load cell installed 3.Alloy steel construction throughout 4.Support bolt to avoid overturn

load cell weighing module  

Dimensions(mm) 

     Fixed-Pin Module 

Anchors the system by providing a fixed point with no horizontal Movement.For best accuracy,attach piping and electrical connections to the scale at this point.

    Semi-Floating Module

Keeps the scale from rotating around the fixed pin. Scale floats enough to allow vessel to expand contract without introducing an error-causing bind in the weigh system.

    Full-Floating Module 

Supports load only. Suspension unaftected by expansion/contraction.

 Specifications of load cell installed

 Emax(Max. capacity)t0.5~2250
 SensitivitymV/V2.0±0.002
 Accuracy class   C2  C3
 Maximum number of verification intervalsnmax20003000
 Minimum load cell verification intervalVminEmax/5000   Emax/10000 
 Combined error%F.S≤±0.030 ≤±0.020
 Creep%F.S/30min≤±0.024≤±0.016
 Temperature effect on sensitivity%F.S/10°C≤±0.017≤±0.011
 Temperature effect on zero%F.S/10°C ≤±0.023  ≤±0.015
 Zero balance  %F.S  ±1.0
 Input resistance  Ω  380±10Ω
 Output resistance  Ω   352±3Ω 
 Service temperature range  °C  -30~+70
 Safe overload  %F.S  150
 Ultimate overload  %F.S  250
 Recommended excitation voltage  V DC  10~12
 Insulation resistance  MΩ/50V  ≥ 5000
 Protection class   IP67/IP68
 Load cell material   Alloy steel / Stainless steel
 Cable Size3m(0.5~2t)/4m(3t)/5m(5t)/6m(10t) /10m(20t~25)
 Cable color code: Exc+[Red] ; Exc-[Black] ; Sig+[Green] ; Sig-[White] ; Shield[yellow]

1. XBA load cell installed2. Low shape, compact structure, install easily3.The object which support the weigh can reset automatically for keep the correct position to load4. Fixed floated, half-ranged can overcome the influence for transform5. Intercalate bolts prevent from turning, remove the influence of  the wind power.

6. Protected against corrosion by nickel-plated treatment

 Application 

Suitable for floor scales, blending & mixing  systems and batching systems, etc.    