Inverter
1. Advanced DSP---digital control technology
2. Pure sine wave output3. LCD+LED display,friendly Human Computer Interaction,can checking working state,load state,enviroment state any time4. Input and Output Isolated,strong ability for shock from load,surge protect.5. High efficiency inverter,low waste when no load.6. Advance outlook7. With Input over/Low voltage protection; output overload,short circuit protection; AC Bypass high voltage and Low voltage8. Bypass first or Inverter first can be choice by client.9. suitable for unattended station. Intellectualization communication1. RS232 communication2. TCP/IP3. Dry card for Long-distance alarm Telecom Power pure sine wave inverter(24V/48V)EA-IVS6000 series was specialy design for telecom,suitable for 48VDC,-48VDC,24VDC Station.When AC power working normally,the Power will be supplied by AC through STS to the important load,when AC power stop working or working abnormal,It will transfer to Inverter working. Technical Specification:Item | 1000VA | 2000VA | 3000VA | 4000VA | 5000VA | 6000VA | |
Working mode | Pure inverter/Line-interactive | ||||||
DCINPUT | Input voltage | 24V or 48V | 48V | ||||
Input current | 50/25 | 100/50 | 150/75 | 100 | 125 | 150 | |
shut down voltage | 20V-30V or 40V-60V | ||||||
switch on voltage | 22V-28V or 46V-57V | ||||||
feed back current | <10% | ||||||
ACINPUT | bypass voltage | 220v±15% | |||||
Input current | 4.5 | 9.1 | 13.6 | 18.2 | 22.7 | 27.3 | |
BP transfer time | <5ms | ||||||
ACOUTPUT | Capacity(VA) | 1000VA | 2000VA | 3000VA | 4000VA | 5000VA | 6000VA |
Power(WT) | 800WT | 1600WT | 2400WT | 3200WT | 3500WT | 4200WT | |
Output wave | Pure sine wave | ||||||
Output current | 3.6 | 7.2 | 9.5/10.8 | 14.5 | 16 | 19.1 | |
Output voltage | 220V±1.5% | ||||||
Output Frequence | 50±0.1% | ||||||
THD | <3% | ||||||
action timeLoad 0%-100% | 5% | ||||||
(PF) | 0.7/0.8 | ||||||
overload capacity | 120% 30s | ||||||
Inverter efficiency | >85% | ||||||
Workingenviromrnt | Isolation ability | 1500va 1min | |||||
Noise(1m) | <40DB | ||||||
Temperature | from -25 to +50 | ||||||
humidity | 0-90% | ||||||
Working height | <1000m | ||||||
Cooling way | Wind cooling | ||||||
Indication | LCD display | Input/output voltage,output frequence ,humidity, | |||||
Inverter statues | AC normal,inverter normal,BAT low,overload | ||||||
Protection | low/high input voltage,output overload,short circuitAC high/low voltage protection | ||||||
Dimension | 2U/19' rack | ||||||
Weight | 7KG | 8KG | 11KG | 12KG | 14KG | 16KG | |
Out put connection way | socket/terminal | Terminal |
Inverter( 1-5KVA)