Welcome to ECVERY
variable frequency convertor
variable frequency convertor
Supplier Info
[China Supplier]
Contact Person : Mr. an jia
Tel : 86-513-88758898,88755311
Fax : 86-513-88755315
Product Detail
widely used for the energy-saving application of the normal motors of fans, pumps, compressors, mills, conveyors and lifts

1. Variable Frequency Drive characteristicsVFD is a masterpiece of outstanding performance and high reliability, which is widely used for the energy-saving application of the normal motors of fans, pumps, compressors, mills, conveyors and lifts. HARSVERT-A series VFD uses new type of IGBT with advanced microcomputer control.

High-High voltage resource VFD, direct 3, 3.3, 4.16, 6, 6.6, 10, 11 kV input, direct 3, 3.3, 4.16, 6, 6.6, 10, 11 kV output, no output up-transformer required. Integrated dry type phase-shifting transformer design. The user only connects input/ output power cables and control cables. Each VFD is made inspection before leaving the factory. Input power factor of more than 0.95 with the load of 20~100%, very low harmonic voltage/current, no power factor correction capacitor and harmonic filter required Output sine step PWM waveform, no output filter required, VFD is directly connected to normal motor without the harm to the insulation of the motor and the cables. Soft start ability of VFD greatly reduces the impact to the power grid when the motor starts. Output waveform of VFD does not bring the resonance of the motor. The torque impulse is less than 0.1%, which greatly reduce the resonance of the fan. VFD has frequency-skipping function to avoid the resonance of the system. It is no limit to the length of the output cables. The motor is not influenced by very small common mode voltage and dv/dt. Integrated microcomputer control and self-diagnosis ability. VFD displays detailed failure message in local interface and send the alarm to user's remote interface. Local/ remote control; Communication protocols, such as Modbus, Profibus, TCP/ IP, DeviceNet, etc. Torque characteristics: VFD can output constant rated torque from 0 to 50/60 Hz with torque step response < 200ms. VFD will output constant power with reduced torque for more than 50/60Hz. VFD can ride through 35% voltage dip to continue operating without trip-off. The mature technology of cascade-connected power cells keeps the good output waveform, which protect the motor and the cables well. IGBT capacity is designed with high redundancy. Cell bypass[OPTIONAL FUNCTION] technology keeps VFD to continue operating when one or two power cells are in failure. Auto re-start [OPTIONAL FUNCTION, FREE] after the recovery of power supply. When power supply is recovered in preset time, such as default time of 20s, VFD will fly start. VFD checks motor speed automatically and trace the speed to fly start again without impact. Flying start[OPTIONAL FUNCTION]. Main circuit is connected to the controller by optical fiber, which make VFD extremely safe and away from electromagnetic disturbance. Multi pulse rectifier technology, high power factor, few harmonics which directly comply with IEEE 519 harmonics standard. Friendly interface based on WINDOWS CE system. Optional redundant design for control power supply. VFD can accept two separate channels of auxiliary power supplies of single phase AC or DC for the controller from the user. The voltage is 110V, 220V, 230V, 380V, or 415V etc. If one channel of auxiliary power supply is in failure, the redundant channel of auxiliary power supply will immediately supply the power for the controller. Automatically optimize the acceleration and the deceleration. Perfect fault monitor and accurate protection. The basic protection includes over voltage, over current, low voltage, phase loss, over load, over heat, earth fault, and short circuit. The failures of VFD include light failure and serious failure. VFD can continue to operate well with light failure. Compatible with the standard analog signal of 0~10V or 4~20mA Integrated PID regulator to make the flexible close control application Cost effective VFD

2.application

Power generation: ID fan, FD fan, Primary air fan, Second Air fan, Condensate exhausting pump, Boiler feed water pump, Slurry pump. Metal: Dust air fan, Primary air fan, Pump, Compressor. Oil & Gas: Oil transferring pump, Water injecting pump, Electric submersible pump, Water Pump, Compressor. Cement: Pre-heater fan, Coal mill fan, Cement mill fan, Bag house fan, Raw mill fan, Lignite Mill Filter Fan, By Pass Filter Fan, Kiln. Mining: Conveyor, Lift, Pump. Water: Pump.

variable frequency convertor

Related Products
Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.