ac power source with variable frequency,400hz Variable Frequency AC Power Source, Variable Frequency AC Power Source
3phase input and 3phase outputInput: 380VAC 50/60HZOutput: 380VDC 50HZ, 60HZ, 400HZ
400HZ For Military and Aircraft
Military: 115VAC 400HZ
Aircraft: 115VAC 400HZ
Output Phase High Voltage: 0-300VAC
Output Phase Low Voltge: 0-150VAC
A-B-C 3Phase Switch AutomaticCapacity: 6kva-200kva
ac power source with variable frequency,400hz Variable Frequency AC Power Source, Variable Frequency AC Power Source Information:
The 400Hz Variable Frequency AC Power Source is the mainstay of aircraft ground support and are designed to meet such power requirements of military, commercial aircraft as well as 400Hz avionics.
400Hz Variable Frequency AC Power Source which convert 60Hz or 50Hz electrical power to 50Hz, 60Hz, or 400Hz electrical power to run your equipment
ac power source with variable frequency,400hz Variable Frequency AC Power Source, Variable Frequency AC Power Source Specification:
Model (YK-BP) | 8806 | 8810 | 8815 | 8820 | 8830 | 8845 | 8860 | 88100 | 88150 | 88200 | |||
Rated Capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 100KVA | 150KVA | 200KVA | |||
Capacity of each phase | 2KVA | 3.3KVA | 5KVA | 7KVA | 10KVA | 15KVA | 20KVA | 33KVA | 50KVA | 67KVA | |||
Circuit mode | IGBT/PWM | ||||||||||||
AC input | Single phase 220V/50Hz60Hz | Tri-phase 380V/50Hz60Hz | |||||||||||
AC output | Phase | Tri-phase ( phase potential difference 120°±2°) | |||||||||||
voltage | Low range | Phase voltage :0V-150V(line voltage:0V-260V) | |||||||||||
High range | Phase voltage:0V-300V(line voltage:0V-520V) | ||||||||||||
Frequency | 400Hz | ||||||||||||
Man current of each phase | 0V-150V | 16.8A | 28A | 42A | 58A | 84A | 126A | 168A | 276A | 416A | 556A | ||
0V-300V | 8.4A | 14A | 21A | 29A | 42A | 63A | 84A | 138A | 208A | 278A | |||
Frequency stability rate | ≤±0.1% | ||||||||||||
Load stability rate | ±0.5% | ||||||||||||
Waveform distortion | Sine wave,≤±2%(linear load) | ||||||||||||
Respond time | Max 2ms | ||||||||||||
Indication resolution | Digit frequency | 4 digit resolution 0.1Hz | ABC phase change optionally | ||||||||||
Digit voltage | 4 digit resolution 0.1V | ||||||||||||
Digit current | 4 digit resolution below 4A 0.001A above 4A0.01A | ||||||||||||
Digit power | 4 digit resolution below 200W0.1W above 200W1W | ||||||||||||
Power factor | 4 digit resolution 0.001 | ||||||||||||
Protector | Input no fuse switch, output fuse switch, electronics circuit speed detect the over voltage, over current, over load, over temperature, short circuit and automatic jump protection and alarm. | ||||||||||||
Cooling | Forced fan cooling | ||||||||||||
Environment | Operation temperature | -10 to 60 | |||||||||||
Related humility | 0-90%non condensing |
ac power source with variable frequency