Ads by Google
High Transform efficiency, fast start; Pure sine wave output waveform; Strong adaptability and stability; With automatic over currency and output short circuit protection to avoid damage the equipment; Safe and reliable with built in fuse
Function details
Model | MK-6000P-121 | MK-6000P-241 | MK-6000P-481 | MK-6000P-122 | MK-6000P-242 | MK-6000P-482 |
Rated power | 6000W | 6000W | 6000W | 6000W | 6000W | 6000W |
Peak power | 12000W | 12000W | 12000W | 12000W | 12000W | 12000W |
DC input voltage | 12V | 24V | 48V | 12V | 24V | 48V |
AC output voltage | 110VAC | 220VAC | ||||
No-load current | 2A | 1A | 0.5A | 2A | 1A | 0.5A |
AC output frequency | 60HZ | 50HZ | ||||
AC output waveform | Pure Sine Wave | |||||
Waveform distortion | THD below 2%(Linear load) | |||||
Efficiency | over85% | over88% | over90% | over85% | over88% | over90% |
DC input voltage range | 10.5-15V | 21-30V | 42-60V | 10.5-15V | 21-30V | 42-60V |
Low Voltage Alarm | 10.5+/-0.3V | 21+/-0.3V | 42+/-0.3V | 10.5+/-0.3V | 21+/-0.3V | 42+/-0.3V |
Low Voltage Shutdown | 10+/-0.3V | 20+/-0.3V | 40+/-0.3V | 10+/-0.3V | 20+/-0.3V | 40+/-0.3V |
Over Voltage Protection | 15.5+/-0.5V | 31+/-1V | 62+/-2V | 15.5+/-0.5V | 31+/-1V | 62+/-2V |
Low Voltage Recovery | 12+/-0.5V | 24+/-1V | 48+/-2V | 12+/-0.5V | 24+/-1V | 48+/-2V |
Over Voltage Recovery | 14.8V | 29.5V | 59V | 14.8V | 29.5V | 59V |
Protective Function | Low/Over voltage | LED Red light, automatic recovery | ||||
Over load | LED Red light, automatic recovery | |||||
Over temperature | LED Red light, automatic recovery | |||||
Short circuit | LED Red light, automatic recovery | |||||
Input reverse connection | Fuse Burn-out | |||||
Working Temp. | 0-40C | |||||
Storage Temp. Humidity | (-30C)-70C | |||||
Dimension | 545*200*146MM | |||||
Weight | 14KG |
6000watt dc to ac inverter