Technical parameters
| SolarMax2000S | SolarMax3000S | SolarMax4200S | SolarMax6000S |
DC input |
| |||
Maximum PV power installed | 2300W | 3300W | 5000W | 6000W |
Maximum power tracking range | 100…550VDC | |||
Maximum open circuit voltage | 600 VDC | |||
Standard test conditions, the design of the PV array voltage range Wai |
550 .. 635 VDC | |||
Operating Current | 0…11A DC | 0 ... 11 ADC | 0 ... 22 ADC | 0 ... 22 ADC |
Ripple current | < 4% peak-peak |
AC output |
| |||
Rated output | 1800W | 2500W | 23800W | 4600W |
Maximum power | 1980VA | 2750VA | 4180VA | 5060VA |
Grid voltage | 3 * 400 +10% / -15% VAC | |||
Operating Current | 0 ... 31 AAC | 0 ... 38 AAC | 0 ... 46 AAC | 0 ... 54 AAC |
Power Factor | > 0.98 | |||
Frequency | 50 +/- 0.5 Hz | |||
Harmonic current distortion | < 3 % |
System |
| |||
Bad loss | 2~7W | |||
Maximum efficiency | 96% | |||
European efficiency | 94.8% | |||
Environmental Operating Temperature | -20C~+40C | |||
Protection class | IP20 | |||
Topology | duration time modulation(IGBT)with transformer | |||
Humidity | 0~98%Non-condensing | |||
CE standards | EN61000-6-2,EN61000-6-4 ,EN50178 | |||
Certificate | TUV Rheinland “TYPEAPPROVED” | |||
Show | Two lines, LCD (backlit) | |||
Data communication | Integrated RS232/RS485 Interface | |||
Size(W×D×H) | 120×80×180cm/cabinet | |||
Weight | 735kg | 275kg | 370kg | 370kg |
Group string solar grid-connected inverter