Welcome to ECVERY
vacuum slimming Equipment LT-N002
vacuum slimming Equipment LT-N002
Supplier Info
[China Supplier]
Contact Person : Ms. Xiao Finna
Tel : 86-20-86297128
Fax : 86-20-86297098
Product Detail
This vacuum slimming Equipment: 1. Simple and easy operation , 2. Adopt the newest cavitation lipolysis and tripolar rf techn

I. Introduction of vacuum slimming Equipment LT-N002

1. Treatment theory of Ultracavitation+Monopolar RF+Tripolar RF+Vacuum liposuction system

Ultracavitation+Monopolar RF+Tripolar RF+Vacuum liposuction system is the most advancedtechnology , It combines the advantage of Ultracavitation,Vacuum liposuction and RF together. TheUltracavitation uses ultrasonic cavitation effect to cause the air bubbles around lipocyte membranes to breakup, and then the broken lipocyte will be absorbed and metabolized out of human body by lymphatic system.Ithas an effective treatment result for weight losing. burning fat cell , explode fat cell etc .

Also we use 1 MHz radio frequency to alternate the electric field in the skin from positive to negative. Itwill produce heat under dermis then the initial collagen denaturation. Subsequent neocollagenesis thenfurther tightens the dermal tissue and make the skin tightened, smooth and fresh.

Tripolar RF energy is transmitted to the place between three electrodes; the current permeates targettissue and generate heat. It will produce the equal and cycle energy between three electrodes ,because ofthat .The patient will feel more comfortable during treatment , it will get good result on skin lifting ,tightening slack skin . wrinkle removal etc

Vacuum fat-liposuction system can promote tissue metabolism ,repel the cellulite .tighten the flabbyskin ,strengthen the skin elasticity etc,As It will bring the gas and vapour on the between skin and treatmenthead, so it will give a positive pressure on liquid molecule through the expansion cycle on body , Theexplosion effects inside and outside the cells will increase the molecular movements .so as to achieve an highenergy state .then make the lipocyte dissolving quickly .it will give you slimming body ,Its effect will last fora long time . at the same time, it can enhance the muscle elasticity and improve the cell metabolism .

The theory of newest tripolar rf

Tripolar rf technology painlessly delivers focused and optimal RF energy to the skin surface and tosubcutaneous fat layers. Controlled energy is delivered via three or more electrodes , centered between them,and limited only to the treatment area. This focused delivery results in improved treatment efficacy thatprovides immediate visible results from the first treatment. The treatment is painless and pleasant because ofthe relatively low power needed.

The energy of tripolar rf permeates epidermis and take effect on the collagen-rich dermal tissue directlywhich makes water molecules in the skin move. The move produces controllable heat and results incontraction of collagen and generation of new collagen and dermal remodeling .as a result, the skin lookstighter, wrinkle reduce gradually .

Tripolar rf integrated preset parameters allow operator to choose between body and facial treatments.Targeted facial treatment regenerates collagen fibers in the dermis layer. Targeted body treatments shrink fatcells in the hypodermis layer and accelerate collagen regeneration.

The Tripolar RF is the latest technology which is very comfortable for patient during the treatment . Andthe energy output is more evenly . the treatment results is much better than monopole RF and bipolar RF.

2. Applications

1) Ultrasonic cavitation head(cavitation explode) for burning fat cell , explode fat cell,surplus fat ;

2) Monopolar RF(lipolysis RF) head for body shaping,slimming,fat burning ; fat &cellulite reduction ;

3) Tri-polar RF head for skin tightening , skin lifting ,wrinkle removal on face and body with big and smalltreatment head

4) Vacuum liposuction head for slimming ,remove surplus fat cell ;

4. Parameters and specification

5. Taboo(forbidden to use )

1) Serious disease, such as heart disease, gastric ulcer, serious gastropathy, duodenal ulcer, high blood pressure, diabetes

2) Pregnant women, lactating women, an abdominal operation within 3 months, menstrual period, metal pieces in body (suchas heart jumping devices etc)

3) Do not do treatment around testis

4) Food of High-calorie, High fat, and High protein, better to light food

5) Taking other diet medicine, we suggest that stop taking those diet medicines and do ultrasonic treatment 1-2 months later;or prolong treatment period.

6) Can not do ultrasonic treatment under empty stomach, must be 1 hour later dinning

II. Operation Security Instruction

1. Security introduction of the machine

This fat reduction system is high-tech medical beauty equipment with safety and reliability, mainly for removing surplusfat, burning surplus fat, Lymphatic Treatment, skin tightening ,wrinkle removal and improving skin elasticity. etc.

For the safe and effective use, operators and assistants must know below

It will generate the hot during ultrasonic cavitation and tri-polar RF operation,The operator should ask the patient whether it is very hot or not on the treatment skin,It is normal that the patient will feel a little hot with ultrasonic cavitation and tri-polar RF ,in fact the patient will feel verycomfortable for tripolar RF treatment .

Patients:The Safety of patients mainly rely on well-trained physicians as well as the layout of the appropriate treatmentroom. Cultural quality of life of patients is also very important; they should understand the principles oftreatment. Patients should be protected effectively when treatment.

Operators:The operator should ask the patient whether it is hot or not (a little not is normal )

[MAIN ALARM]

For safe using, should carefully read the alarm notice:

1.Except the authorized mechanic, any others have no right to examine and repair theFG660 structure; especially innerstructure inside of machine that including electrical source,RF system ,treatment head etc .

Notice the dangerous high pressure inside.

2. Make sure whether the voltage of the system is accordant with your local voltage or not.(220V/110V AC)

3. Maintenance must be done after turning off the machine and drawing out the power line. Or it’s most possible to hurtpeople and damage the equipment.

4. keep the treatment head clean after treatment ,

5. Don’t place treatment head, electrode cathode and patient’s heart in the same level

[Alarm]

i. The operator should pay more attention to the treatment situation during treatment

ii. Don’t make the tripolar and ultrasonic treatment head close to metal and conductor, treatment head should be hung upwhen don’t use it ,

The treatment head should be point at treatment area when using it

2. Safety of LVD and EMC

1. Keep close both panels and cover board

2. High pressure inside equipment. It’s possible to deposit electricity in some parts even after switching off. So it’s not allowed to disconnect equipment beyond the factory’s authorization.

3. In maintenance, please turn off machine and disconnect power supply firstly; and then do observe in person.

4. Ground line connect.

[PREVENT FIRE]

1. The temperature will rise after absorbing wave energy, so please take actions to reduce the flammable risk on treatmentparts or around area.

2. Do not use ethanol, acetone or other flammable things on skin before treatment. If necessary, please use soap or water.

3. When listerizing the treatment head or other parts by ethanol, please wait till dry.

[AUTOMATICALLY INSPECTION]

After turning on the machine, it will be inspecting automatically. About 1-3 minutes running automatically, then it enters intothe next step.

III. Operation instructions

I. welcome LCD display

Turn on machine, and LCD display as following:

   

Treatment head

SOME NOTICES :

1. Adjust energy from low to higher step by step.

2. don’t keep treatment head electrode cathode and patient’s heart in the same level

3. If want to stop treatment, please release pedal firstly and then move probe; or the patient mayfeel electric shock more or less, or small painful.

The detials operation process :

1) Cavitation explode

1. Put some cooling gel on the skin before treatment (such as: the abdomen, buttocks, thighs) ,it ismore convenient for the operator to move the treatment head easily .

2. Set working hours (about 10 to 15minutes), adjust the output intensity (5w/cm2 ~ 25w/cm2)

3. touch "Start" button, the machine will start to work,

4. Beautician grip the treatment head touch the skin closely ,and make slow circular motion or astraight line go and back movement, don’t stop the treatment on the same place.

5. Can not operate in the back of body, we must avoid the bone bits

6. The machine will be stop automatically after the setting time is over.

7. clean skin and treatment head with hot towel

2) Monopolar rf for dissolving fat cell (lipolysis RF)

1. Select pulse or continuous mode, adjust the output intensity (10J/cm ~ 30J/cm), set the workinghours (about 15 minutes).

2. Touch "Start" button,machine start to work. Beautician grip the treatment head touch the skinclosely ,and make slow circular motion or a straight line go and back movement, don’t stop thetreatment on the same place if choosing continuous mode .

3. The machine will be stop automatically after the setting time is over

4. clean skin and treatment head with hot towel

PS “T” mean the output energy time (recommendation from 1-2). “D” mean the pluse interval (0.5-1)

3) Tripolar RF skin tightening (abdomen ,buttocks, thigh ,face etc)

1. please put about 3mm cooling gel on the skin before operation , according to different face or bodyteatement. choose big or small tripolar treatment head ,

2. Choice of work mode, the machine set up 10 working models ,All of them are pulsed or continuouswave output mode, adjust the output intensity (10J/cm2 ~ 30J/cm2) set the working hours (about15 minutes)

3. Touch “Start” , machine start to work

4. The machine will be stop automatically after the setting time is over

5. clean skin and treatment head with hot towel

PS “T” mean the output energy time (recommendation from 1-2). “D” mean the pluse interval (0.5-1)

4) Vacuum liposuction system :

1. put some essential or slimming oil on the skin, the treatment head will suck the skin. It is veryconvenient for operator to sli p the treatment head, it can also get a result of massage via suctionpressure.

2. Select negative pressure(Vacuum) and strong sound wave mode, adjust negative pressuresuction and strong output intensity of sound waves, set working hours (about 10-20 minutes eachsessions ).

3. Beautician hold the treatment head touch the skin closely , and orderly slow-moving, themovement should be coherent or pull up, the operator should adjust the intensity of suctionpressure according to the guests endurance ,vertically forward move(go-return) for fat dissolving .

the suction pressure makes dissolving fat cell molecules in the body move unitl out of body vialymphatic drainage system . the vacuum liposuction head can also give body a massage.

Recommended operating procedures and parameters setting

1. please take shower before treatment (clean the skin )

For surplus fat patient ,Start with cavitation treatment head for explode and breaking fat cell(bout 15 minutes)

2. Monopolar RF for dissolving fat and lipolysis . (about 10 minutes)

For little fat patient . you can choose tripolar rf head (about 15 minutes )

3. Clean the skin again , put some essential oil on the skin and massage the fat body ,imporve thelymphatic drainage system and slimming care .(about 20 minutes)

( function(){ var aBigImageSrc = [ 'http://i00.i.aliimg.com/photo/v1/700828376_1/vacuum_slimming_Equipment_LT_N002.jpg' , 'http://i00.i.aliimg.com/photo/v1/700828376_2/vacuum_slimming_Equipment_LT_N002.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); vacuum slimming Equipment LT-N002

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.