Welcome to ECVERY
T8-T5 bracket converter fluorescent fittings/T5-T8 fluorescent fixture
T8-T5 bracket converter fluorescent fittings/T5-T8 fluorescent fixture
Supplier Info
[China Supplier]
Contact Person : Ms. Zhang Fancy
Tel : 86-573-87832022
Fax : 86-573-87836808
Product Detail
- Saving power more than 80% - Pure tri-phosphor tube -8000h-10000h -CE&RoSH

 Specifications: 8W,14W,21W,28W

1. Comparing with magnetic T8, it will save 35%-50% electricity which save power bill by 35%-50%.2. No need to change anything on the original fixture.3. Easy installation, the replacing procedures are the same as replacing a normal tube. Will much save the labor cost of Energysaving Lighting Reconstructing Program.4. Power factor improved from 0.5(traditional magnetic ballast) to >0.98. The current decreases by 3-5 times which will help to reduce the wastage of electricity system and thus save energy.5. Rapid start without flickering, even under low temperature or low voltage.6. CRI>80, get better color performance.7. Hi frequency electronic ballast, protecting eyes from 50Hz flickering of light caused by magnetic ballasts.8. Noises free.9. Reduce heat during operation. It indirectly saves energy because it helps to decrease the load of air-conditioning system.10. Complete abnormal protection function prevent from burning on accident, life end or gas leak etc.11. The fixture reflector can distribute the light to right direction, improve the system efficiency and then save more energy.

How to replace:1. Turn off power supply2. Take away the T8 Lamp3. Take away the starter4. Take away the rectify capacitor, if not, the power factor of the capacitor will be reduced to 0.55. Install the T5 lamp tube what in a same way of T8 Lamp6. Turn on the power, then finish the installation.

How to replace:1. Turn off power supply2. Take away the T8 Lamp3. Take away the starter4. Take away the rectify capacitor, if not, the power factor of the capacitor will be reduced to 0.55. Install the T5 lamp tube what in a same way of T8 Lamp6. Turn on the power, then finish the installation.

T8 to T5 fluorescent light fixturethe reflecter can be remove

(replace Old T8 fluorescent tube directly)T5-14w replace T8-18w(20w)T5-21w replace T8-30wT5-28w replace T8-36w(40w)T5-35w replace T8-58w

T8-T5 bracket converter fluorescent fittings/T5-T8 fluorescent fixture

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.