Themal Shock Test Chamber HTSA Series
About
Higher performance The HTSA Series aims at fulfilling high-level requirements for thermal shock testing.The advanced model achieves 1000-cycle consecutive tests without defrosting (option), and offers reduced temperature recovery time, heat up and pull down time.Features an eco operation mode for more energy savings. | |||||||||||||||||||||||
| |||||||||||||||||||||||
Specifications
|
Features
Short temperature recovery timeThe maximum temperature recovery time at upstream air for 2 zone test (+150°C and -65°C) and 3 zone test is only 5 min. (10 min. for TSA-201S and TSA-301L)Great uniformityHorizontal air flow system offers excellent specimen temperature uniformity.Efficiency thanks to specimen temperature control (option)Thanks to this feature, the equipment achieves set temperature attainment with rapidity and accuracy.STT function (option)Thanks to the specimen temperature monitor with trigger, exposure time starts only when the specimen has reached the set temperature, leading to more precise test results.User-friendly controllerThe LCD touch-screen controller allows easy check of the test patterns, temperatures settings, test cycles and graph displays.Reduced load currentReduced operating noiseEnergy-saving
Reduced operating timeThe eco operation mode reduces the operating time by temporarily suspending following periods:- Pre-cooling of the low temperature chamber during high temp. exposure,- Preheating of the high temperature chamber during low temp. exposure.Thanks to the eco operation mode, power consumption is dramatically reduced especially for long exposure time, and tests requiring many cycles. (except HTSA-41L)Unique chamber structure(Patent No. 3514735)HONGZHAN’s unique design enables 1000-cycle (500-hour) without defrosting in 2 zone test. The structure prevents outside air to penetrate, which is usually causing frost. Constant environmental conditions are maintained, thus expanding the defrost-free operation range.*Models supporting defrost-free operationHTSA-71H-W: 1000 cycles (500 hours)HTSA-201S-W: 500 cycles (500 hours)Continuous operation is not supported forsome test conditions. | Cumulative power consumption during eco operation1000-cycle test time comparison (option) |
Options
Defrost-free operationSpecimen temperature controlSpecimen temperaturemonitor with trigger functionPaperless recorderTemperature recorder (digital)Temperature recorder forfuture installationRecorder terminalThermocoupleExposure signal outputAdditional overheat protectorExternal alarm terminalEmergency stop switchTotal cycle counter | Auxiliary cooling injector (LCO2)Auxiliary cooling injector (LN2)Built-in air compressorAutomatic doorAdditional cable portCable port rubber plugCastersSpecimen basket / shelf bracketHeavy-duty shelvesChamber dew trayFixture for securing bodyExhaust ductColor specificationCommunication functionsPower cable |
Contacts:Ms lucky tam
Tel:86-138 2929 1719 /86-769-23183767
www.testchamber.com.cn/ www.hongzhan.com.hk
Machine stock/Climate Test chamber/Thermal Shock test Chamber/test chambers/environmental test chambers/salt spray test chamber