Ads by Google
Sidewall fireproofing board of tunnel
Description | Sidewall fireproofing board of tunnel |
Raw Materials | magnesium oxide, magnesium chloride |
Standard Size | 1220mm×2440mm |
Thickness | 16mm |
Basic Color | white |
Water Content | ≤10 |
Water Absorption | ≤40 |
Manufacturing Standard | GA160-2004 |
Fire Resistance | Incombustibility Class A |
Thermal Conductivity | Average≤0.20W/MK |
Bending Strength | Transverse≥11.0N/mm3 Vertical≥8.5N/mm3 |
Series | plain,electrostatic,metal,wood grain |
Packing | Wooden pallet |
Trade Terms | FOB SHANGHAI, CNF, CIF,CFR |
Payment | T/T, L/C at sight |
Leadtime | 15days after receipt of the T/T deposit or L/C. |
Main Characteristic | 1.Fire proof and non combustibility |
2.Non-flammability: GB8624 grade A | |
3.Waterproof: resistant to deformation in wet environments | |
4. Weight: Light weight,(volume weight: 1.02-1.06g/cm3) | |
5. Strength: Bendable and impact resistant | |
6.Invariability: Resistant to deformation in wet, hot and dry conditions | |
7. Aging resistance | |
8.Heat Resistance: Thermal conductivity of 0.020W/(m.°C) | |
9.Durability: Resistance to halogen accumulation, long lasting strength | |
10.Cold resistance: can be used at 40 degree | |
11.Installation: Easy to work, fix and decorate | |
12.Environmentally friendly |
Technical parameters of fireproofing board for tunnel
Items to be inspected | Technical requirements and parameter | ||
Areal density(kg/m2) | ≤25 | ||
Allowable difference between edge flatness and diagonal line | Not inferior to requirements of GA160-2004,4.3.3 | ||
Bend strength in dry condition(Mpa) | Satisfies the requirements of GA160-2004,4.4 | ||
Bend strength in condition of saturated moisture absorption (Mpa) | No less than 70% of bend strength in dry condition | ||
Deformation rate after moisture absorption(%) | ≤0.20 | ||
Performance of anti-dehylogenation | No bead and no damp | ||
Toxicity of generated fume | Not inferior to ZA1 of GB/T20285-2006 | ||
Water resistance (h) | ≥720 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | |||
Acid resistance | ≥360 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | |||
Alkaline resistance(h) | ≥360 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | |||
Moisture and heat resistance(h) | ≥720 | ||
No cracking, aliquation,dropout after test, slight swell and color change is allowed | |||
Water absorption rate (%) | ≤12.0 | ||
Fire resistance performance(h) | standard | Limit of fire resistance (h) | ≥2.0 |
HC | Limit of fire resistance (h) | ≥2.0 | |
RABT | Limit of fire resistance (h) | During temperature rise≥2 | |
During temperature drop≥1.83 |
Sidewall fireproofing board of tunnel