Welcome to ECVERY
Syringe Pump
Syringe Pump
Supplier Info
[China Supplier]
Contact Person : Mr. Chen Zhiqiang
Tel : 86-21-62328378
Fax : 86-21-62321266
Product Detail
This pump adopts high-tech design and has various advantages in clinical practice.

Syringe Pump 

This Syringe pump is an indispensable medical instrument used for injection.

This pump adopts high-tech design and has various advantages in clinical practice, such as easy & safe operation, high-precision, intelligent alarm, self-testing, stable injection during long time, dispelling remained fluid, etc

In addition, the operation of injection is automatically controlled by microcomputer and all working parameters in real time can be directly read on its LCD screen.

This pump is equipped with both AC & DC power supply devices and applicable to most departments of hospital (e.g. surgery, internal medicine, Paediatrics, Gynaecology, ICU and CCU ward, etc) or for emergency treatment outdoor.

  

SPECIFICATION & FEATURES

Applicable to all brands of disposable syringe.Clear-displaying on LCD screen remaining time of injectionAutomatically controlling syringe moving speed in accordance with specific volume and time preseted for each injection.

TECHNICAL PARAMETER

Power Supply

AC: 220V or 110V (at option)

DC: Inner Power 9.6V±0.5V

4 hours of continuous operation at 5ml/h when full charge

Power Consumption

≤20VA

Dimension

320mm x 148mm x 152mm

Weight

2.5kg

Applicable Syringe

All brands of disposable syringe by volume of 10ml, 20ml, 30ml & 50ml

Flow Rate Option

0.1~199.9 ml/h in 0.1 ml/h increments

Total Infused Volume

0.1~999.9 ml in 0.1 ml increments

Infusion Accuracy

±3% (0.1ml/h~10 ml/h)

±2% (10 ml/h~199.9 ml/h)

Quick-feed

200 ml/h (10ml injector)

300 ml/h (20ml injector)

300 ml/h (30ml injector)

300 ml/h (50ml injector)

Occlusion Pressure

Low:    (40±40kPa)

Medium: (60±10kPa)

High:   (120±10kPa)

Audible & Visual Alarm

Near empty, Empty, Occlusion, Remove, Low battery, Device disengaged, Motor trouble, Falling of the injector, AC power fail.

Specific Functions

Time and volume mode, Indicating the remaining time of injection, Automatic check injector specifications, KVO functions, Total indication of transfusion, Quick-feed/Prime function.

Working Condition

Environment Temperature: +5~+40

Classification

II BF type IPXI

Syringe Pump

Related Products
Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.