Welcome to ECVERY
clinical instruments detergent
clinical instruments detergent
Supplier Info
[China Supplier]
Contact Person : Mr. Wang Michael
Tel : 86-28-65988030
Fax :
Product Detail
Enzyme Detergent for surgical instruments, enzymatic detergent,detergent for medical instrument

Provides simple one-step cleaning of instruments and equipment. Contains main 3 enzymes ( proteolytic, lipase, amylase) and a powerful detergent base that remove organic waste materials within minutes. Neutral pH and noncorrosive- safe for use on endoscopes, medical/surgical equipment, trays, carts and medical table cloth. Economical, just mix 4 ml per litre of water. 2 to 3 minute soak is recommended for washer cleaning, while a minimum 5 minute pre-soak is recommended for manual cleaning.Applied scopes: Effectively penetrates and lifts off tough, dried-on, hard-to-reach organic matter. Specially formulated for endoscopes and general medical equipment, ROS Enzyme Detergent can be easily used anywhere instruments are processed, including GI labs, operating rooms, central supply, OB/GYN offices, outpatient surgery centers, and physician offices. ROS Enzymatic Detergent makes it easy to meet the highest standards for instrument cleanliness prior to high level disinfection or sterilization. Features:1) Rapid action provides rapid results2) With fast-acting ROS Enzymatic Detergent, results begin in just 1-2 minute3) Room-temperature efficacy streamlines processing4) ROS Enzymatic Detergent is effective at room temperature, eliminating the need for hot water5) Easy to rinse detergent does not leave film on instruments or clog scopes6) Suitability for multiple systems consolidates expenses7) Low-foaming feature facilitates use in multiple systems including automatic endoscope reprocesses, ultrasonic cleaners, and washer decontaminators according to manufacturer's recommendations8) Gently removes organic matter from a wide range of instruments9) Neutral pH reduces risk of instrument damageUsage: For manual use in lightly soiled instrument, trays and carts; it can be diluted in as low as 4 ml per liter (1/2oz. per gallon) of water; for heavily soiled instrument, trays and carts; it can be diluted in as low as 8 ml per liter (1oz. per gallon) of water. A minimum 5 minute pre-soak is recommended. Soak instruments immediately after water rinse until all organic matter is removed. For equipment with dried-on matter, extend soak time, use 8ml per liter (1oz. per gallon) of water.If necessary, mechanically clean equipment, thoroughly rinse equipment, aspirating water through all channels to remove ROS detergent and rough-dry equipment including channels before high level disinfection or sterilization. For use in automated equipment, follow manufacturer's recommendations.Suggestion: If year around temperature of atmosphere is over 32 - 35 deg., we suggest use our powder product and dilute when use.

1

clinical instruments detergent

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.