Product Detail
1.Two optional modes 2.dual CPUs 3.Top pressure sensor 4.dynamically display pressure value 5.Up to 20 IV sets can be added

The Features of Dual Mode Infusion Pump HL-X801E

1.    Two optional modes, drip-rate mode and volumetric mode.

2.    Complies with IEC 60601, high safety designation with dual CPUs.

3.    High brightness LCD display and user-friendly operation interface.

4.    Easy switch among d/min, mL/h and volume/time units.

5.    Available for Bolus mode.

6.    Anti-reverse function on motor to prevent upstream.

7.    Self-check when start up and during infusion.

8.    Top pressure sensor for preventing underflow.

9.    Pressure and air-in-line detection devices both with 8 sensitivities setting, dynamically display pressure value.

10.   IV set management function: Up to 20 IV sets can be added, stored and deleted in memory, convenient for operation after calibration.

11.   Adjustable 8 volume levels of alarm for convenient operation in different environments.

12.   CE certified.

The Specifications of Infusion Pump HL-X801E

Infusion Mode

Drip-rate and volumetric

Pumping Mechanism

Peristaltic finger pump

Optional Infuse Rate Unit

d/min, mL/h and volume/time

IV Sets

Standard IV sets of 10, 15, 20 and 60d/mL, with diameter 3.4 ~ 4.5mm.

Flow Rate Range

1.0 ~ 1200 mL/h

Drip Rate Range

10 d/mL IV set: 1.0 ~ 200 d/min

15 d/mL IV set: 1.0 ~ 300 d/min

20 d/mL IV set: 1.0 ~ 400 d/min

60 d/mL IV set: 1.0 ~ 150 d/min

Increment

From 0.1 mL/h to 99.9 mL/h, 0.1 mL increment;

≥100 mL/h, 1 mL increment.

Flow Rate Accuracy

≤ ± 5% (after calibration)

Drip Rate Accuracy

≤ ± 1.5%

Volume Limit

1 ~ 9999 mL

Volume Infused Display

0 ~ 9999 mL & >9999 mL

Purge Rate

600 mL/h

KVO Rate

1 mL/h

Bolus Mode

Available for Bolus mode, flow rate adjustable.

Occlusion Pressure

Upstream and downstream pressure detection device with 8 sensitivities setting, 40 ~ 140KPa.

Air-in-line Detection

Air bubble detected by ultrasonic and the device with 8 sensitivities setting, 50 ~ 1000μL.

Alarm Volume

8 levels setting

IV Set Management and Flow Rate Calibration

IV sets can be added, stored and deleted in memory,convenient for operation after calibration.

Anti-reverse Function

Anti-reverse function on motor to prevent upstream

Self-check

Self-check when start up and during infusion

Audio and Visual Alarms

Air-in-line, Door open, Upstream occlusion, Downstream occlusion, Infusion finished, No operation, Leakage, Bottom empty, Battery low, Pump error, Motor reverse, AC power lost, etc.

Display

Blue LCD with high brightness

Power Source

AC: 100V ~ 240V, 50Hz/60Hz, ≤ 25VA

Battery

Rechargeable Ni-MH battery: DC12V, 2000mAh, life: ≥ 4 hours at 25mL/h, remaining battery displayed.

Operating Conditions

Temperature: 5°C ~ 40°C

Relative humidity: 20% ~ 90%

Atmospheric pressure: 70 ~ 106KPa

Storage Conditions

Temperature: -20°C ~ 55°C

Relative humidity: 10% ~ 90%

Atmospheric pressure: 70 ~ 106KPa

Classification

Class 2, CF, IPX4

Dimensions and N.W.

150mm x 150mm x 235mm; 2.3kg

Application

Intravenous infusion for various liquid medicines, such as vascular expansion solution, anticancer drug, accelerative procreates drug, liquid nutrient, etc.

Applicable for micro and rapid infusion.

NOTE: The specifications subject to change without prior notice. 

disposable infusion pump

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.