Welcome to ECVERY
iv infusion pump
iv infusion pump
Supplier Info
[China Supplier]
Contact Person : Mr. Hu Rooney
Tel : 86-755-86664839
Fax : 86-755-86664933
Product Detail
1.Compatible with IV sets of any brand, universal type 2.Three working modes and 6 Hours continuous work 3.KVO function

Features:

1. Compatible with IV sets of any brand, universal type. 

2. Automatically calibration for IV sets of any brand. 

3. Three working modes: Drop counting control, Rate control and Time control mode. 

4. 6 Hours continuous work when the battery is fully charged. 

5. Have a unique color LCD and an internal battery with a high capability. 

6. Switch between ml/h and drops/min freely. 

7. Three levels of alarm volume: high, medium and low.

8. Three levels of occlusion pressure: high, medium and low.

9. KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state. 

 

Technical Specifications:

 

PARAMETER

SPECIFICATION

Drop Detector

Outside caliper rotary detector (patent)

Infrared sensor

Control Way

Drop counting and adjusting the delivery rate automatically

Fit IV tubes

20d/ml,60d/ml and other, as well as brown tubes

Pump Type

Peristaltic finger pump

Accuracy

±2%, when delivery rate ≤25drop/min (drop counting & time control mode)   

±3%, when delivery rate >25drop/min (drop counting & time control mode) ±5% (Volume control mode after the correct calibration)

Delivery rate

1.0~1200ml/hr (1.0~99.9ml/h 0.1ml/h per step; 100~1200ml/h, 1.0ml/h )

Delivery time range

1-1999min (1min step)

Volume limit range:

0-9999ml (1 ml step)

Total Volume Range

0-9999.9ml (1 ml step)

Purge Rate

600.0ml/h

KVO Rate

KVO is 1ml/h when the delivery rate≤10ml/h, Otherwise KVO is 3ml/h. 

Occlusion pressure

Three level setting LOW, MEDIUM or HIGH 

Alarms

Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.

Three levels of alarm volume LOW, MEDIUM or HIGH

Bolus function

Bolus rate:10-1200ml/h,Bolus volume: maximum of 100ml

Power source

AC power supply: AC 100 to 240V( +/-10%),50/60Hz;Built-in Lithium Battery: Rechargeable,11.1V,2000mAh.

6 hours of continuous operation

Accessories:

AC power line, Operational manual

Protection Class

Class I, Type CF,IPX4

Dimension /Net weight

130mm*200mm*230mm , 2.5kg

 

 

iv infusion pump

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.