Welcome to ECVERY
IV syringe pump with CE
IV syringe pump with CE
Supplier Info
[China Supplier]
Contact Person : Mr. Tian Ken
Tel : 86-0755-84720597
Fax : 86-0755-84720597-17
Product Detail
IV syringe pump with CE *Double channel iv syringe pump *three working mode syringe pump *automatically syringe pump *CE

Medical IV syringe pump with CE

1, through the calibration, can use any factory production line with national standard syringe, and can accurately control injection flow and monitoring injection process.2, can automatically identify disposable syringe specifications.3, has three working mode: speed mode, regular pattern, weight mode.

 Adapt syringe:Adapt to any manufacturers 30ml) 10ml, 20ml (and 50ml (60ml) disposable needles and syringesThe control accuracy: + 2% (any manufacturer syringe, correct the calibrated)Injection speed adjustable scope and incremental:50ml (60ml) syringe: 0.1 ml/h ~ 1800.0 ml/h20ml (30ml) syringe: 0.1 ml/h ~ 800.0 ml/h10ml syringe: 0.1 ml/h ~ 400.0 ml/hTiming model parameters adjustable scope and incremental:Capacity: 199.9 liquids 0.1 ~ incremental 0.1 ml (ml)Time: 1 ~ 1999min (increment is 1min)Weight model parameters adjustable scope and incremental:Drug quantity: 0.1 ~ 999.9 mg (incremental 0.1 mg)Capacity: 199.9 liquids 0.1 ~ incremental 0.1 ml (ml)Dosage: 0.01 ~ 99.99 ug/kg/min (increment is 0.01 ug/kg/min)0.01 ~ 99.99 mg/kg/h (increment is 0.01 mg/kg/h)Weight: 0.1 ~ 99.9 (incremental 0.1 kg); 100 ~ 300kg (increment is 1kg)Pre note adjustable amount range: 0 ~ p35-51 ml (incremental 0.1 ml)Already note quantity display range: 0.1 ~ p35-51 ml (incremental 0.1 ml)Rapid push note: 50ml 60ml) : (1800.0 ml/h, 20ml 30ml) : (800.0 ml/h, 10ml: 400.0 ml/hKVO speed: 1ml/hAcousto-optic alarm: nearly empty, pushing empty, injection (already throughput is equal to finish gets loose throughput), injector, obstruction, operating errors and battery voltage, etc. Various kinds of alarm, utility power failure or off hints.Power supply: AC220V + 22V, 50Hz + 1Hz; Built-in high-performance rechargeable lithium battery pack: DC11.5 V, 2000mAh. New batteries for electric pump with after 5ml/h rate (the standard specifies GB9706.27-2005 work 8 hours above speed).Note: based on user needs to change the battery specifications, increase the discharge time.Power: 25VA acuitiesCall interface: matchingSecurity level: 1 class CF typeShape dimension: 300mm x 240mm x 250mm (double way)Weight: approximately 3.6 kgRunning environment conditions: temperature 5 ~ 40 °C relative humidity 20 ~ 90%Transportation and storage environment: temperature - 10 ~ 55 °C relative humidity 10 ~ 90%

IV syringe pump with CE

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.