1 TECHNICAL DATA
Operating medium:mineral-base fluid,emulsion,water-glycol,phosphate ester(cellulose fiber just for mineral-base fluid)
Operating pressure(max):11MPa
Operating temperature:-25°C~110°C
Indicating pressure drop:0.5MPa
By-pass valve unlocking pressure:0.6MPa
2 ORDERING INFORMATION
Filter type PMA 160 FT 1 H2 1 B5 Filter Element Type :MAX160FT1
160---
Code | Flow rates(L/min) |
060 | 60 |
110 | 110 |
160 | 160 |
030 | 30 |
FT--
Code | Filtrate media and precision | Βx(c) |
FT | Inorganic fiber, 3μm | β3≥200 |
FC | Inorganic fiber, 6μm | β6≥200 |
FD | Inorganic fiber, 12μm | β12≥200 |
FV | Inorganic fiber, 25μm | β25≥200 |
CD | Resin-impregnated paper, 10μm | β10≥2 |
CV | Resin-impregnated paper, 25μm | β25≥2 |
RC | Stainless steel fiber felt 5μm | β5≥75 |
RD | Stainless steel fiber felt, 10μm | β10≥75 |
RV | Stainless steel fiber felt, 20μm | β20≥75 |
MD | Stainless steel wire mesh 10μm | |
MV | Stainless steel wire mesh 20μm | |
MP | Stainless steel wire mesh 40μm | |
ME | Stainless steel wire mesh 50μm | |
MS | Stainless steel wire mesh 60μm |
1---
Code | By-pass valve |
0 | Without by-pass valve |
1 | With by-pass valve |
H2---
Code | Type of indicators |
0 | Without indicators |
S5 | Visual differential indicators |
H2 | Visual-electrical differential indicators |
1---
Code | Working medium |
1 | :mineral-base fluid, emulsion |
2 | phosphate ester |
3 | water-glycol |
B5---
Flow rates | Code | Port sizes |
030 060 | B3 | G1/2 |
N3 | NPT1/2 | |
M3 | M22 X1.5 | |
110 160 | B5 | G1 |
N5 | NPT1 | |
M5 | M33 X2 |
3 CLEANING FILTER ELEMENT COLLAPSE PRESSURE UNDER RATING FLOW RATES(Unit:1X105 Pa,Working mediun parameter:30mm2/s,0.86kg/dm3)
4 DIMENSIONAL LAYOUT
Filter