Model Name | HDS1022M-N | Bandwidth | 20MHz | Sample Rate ( Real time ) | 100MS/s | Horizontal Scale(S/div) | 5ns/div~100s/div step by 1~2.5~5 | Rise time(at input, typical) | ≤17.5ns | Display | 3.7 inch color display with TFT panel(640×480 pixels, 65535 colors) | Channels | Dual | Input impedance | 1MΩ±2%,in parallel with 20pF±3pF | Record length | Max. 6000 points on each channel | Interpolation | (sin x)/x | Probe attenuation factor | 1X,10X,100X,1000X | Input coupling | DC, AC, GND | DC accuracy(Average) | Average>16:±(5% reading+0.05div) for V | Vertical Sensitivity | 5mV/div~5V/div (at input) | Vertical resolution (A/D) | 8 bit(2 channels simultaneously ) | Max. Input Voltage | 400V (PK-PK) (DC + AC PK-PK, 1MΩ input impedance, Probe attenuation 10:1) | Trigger Type | Edge, Video, Alternate | Trigger Mode | Auto, Normal, Single | Trigger level | ±6 divisions from screen center | Acquisition modes | Sample, Peak Detect and Average | DC gain accuracy | ±3% | Automatic Measurement | Vpp,Vavg,RMS,Frequency,Period,Vmax,Vmin,Vtop,Vbase,Width,Overshoot ,Preshoot,Risetime,Falltime,+Width,-Width,+Duty,-Duty, Delay A→B , Delay A→B | Waveform math | +, -, ×, ÷, FFT | Waveform storage | 4 waveforms | Lissajou’s figure | Bandwidth | 20MHz | Phase difference | ±3 degrees | Communication interface | USB | Power supply | 100V-240V AC, 50/60Hz | Li-ion battery | 7.4V, 6 hours operation |
|