Welcome to ECVERY
X-ray instrument(TD series)
X-ray instrument(TD series)
Supplier Info
[China Supplier]
Contact Person : Ms. wang Helen
Tel : 86-0415-6153617
Fax : 86-0415-6153217
Product Detail
X-ray instrument 1,the qualitative and quantitative analysis. 2,the industrial and laboratory analysis machine.

 X-ray instrument  includes X-ray diffractometer,X-ray crystal analysis equipment and X-ray crystal direction finder.

TD series XRD characteristics:

 *the tertiary non-disturbance isolation protection, 

*the performance is more superior,

*the failure rate is extremely low, 

Allication fields

1,the qualitative phase of the sample or the quantitative analysis,

2,the crystal analysis,

3,the material structure macroscopic stress or the microscopic stress determination,

4,the grain size determination, crystallinity determination and so on.

TD series X-ray diffractometer technical parameters

Name

Items

TD-2500

TD-3000

TD-3500

X-ray tube

(domestic or import)

Type

Tube voltage 60kV(target arbitrary choice Cu.Fe.Co.Cr.Mo)

Focus size

1×10mm2

1×10mm2  or 0.4×14mm2

Maximum output power

2.0kW

2.4 kW or 2.7 kW

X-ray Generator

 

Control mode

Microcomputer automatic 1Kv/step 1mA/step

Maximum output power

5kW

 

X-ray tube voltage

10-60kV

X-ray tube current

5-80mA

2-80mA

Stability

<0.01%

Alarm device

There are Kv too high,Kv too lower,mA too high,mA too lower,no water,X-ray tube over-temperature, machine over-current protection and X-ray tube power protection etc.

Goniometer

structure

horizontal(θ-2θ)

vertical(θ-2θ)

Sample levelθs-θd

Goniometer scanning radius

185mm(150~285mm adjustable)

 

Scanning range

0°~164°(2θ)

-35°~170°

-35°~170°(measuring range)

-180°~180°(θ)

-35°~85°(θs/θd linkage)

-35°~170°(θs/θd single action)

Scanning speed

0.06°-76.2°/min

0.006°-96°/min

Scanning mode

θ-2θ linkage,θ, 2θ   single action,continuous or step scanning

θs/θd linkage, single action

 

Minimum step angle

0.001°

0.0001°

Measuring accuracy

≤0.005°

≤0.001°

Angle positioning speed

120°/min

1000°/min

2θ repeatability accuracy

≤0.001°

≤0.0005°

Recording/ Control Unit

counter

Proportional (PC) or scintillation(SC)

Maximum linear count rate

5×106CPS

1×107CPS

Spectrum resolution(Cu.kα spectrum linear)

≤25%(PC)or≤60%(SC)

≤20%(PC)or≤50%(SC)

Counter high voltage

0-2100V or 0-1100V continuously adjustable

Counter mode

PLC automatic control differential integral mode conversion,automatic PHA,dead time correction

Detector high voltage stability

Excel ±0.01%

Excel ±0.005%

x-ray leakage

less than 0.1 μSv/h

aggregative indicator

Safety indicators

Protection system for double protection, have a big and a small shield, to ensure the safety of the users

Integrated stability

≤0.5%

≤0.3%

Overall dimensions

1100×920×1750mm

         

X-ray instrument(TD series)

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.