RFL-200 Ultra-weak chemiluminescence/bioluminescence detector
RFL-200 Ultra-weak chemiluminescence/bioluminescence detector
Supplier Info
[China Supplier]
Contact Person : Ms. Xue Andrea
Tel : 86-29-85338446
Fax : 86-29-85338446
Product Detail
1.This equipment is a multi-functional ultra weak luminescence detector. 2.reliable quality

RFL—200 ultra-weak chemiluminescence/bioluminescence testing instrument is a multi-functional ultra weak luminescence detector. Its multi-functional detector can be equipped with flow or static liquid detecting device to meet the different requirements of the tests. The instrument has wide dynamic test range and two measurement methods which include energy measurement and charge integration test. The instrument is equipped with high accuracy negative high voltage power source and high accuracy signal amplifying and processing system and VFD digital display.

Besides, the detector is provided with automatic control signal. 

Technical indications

1 Negative high voltage power source* Output voltage   -100~1000V * Stability   0.05% * Output current   ≥5mA 2 Amplifier* Gain   1×,5×,10×,50× * Filter frequency   10Hz,20Hz,50Hz,100Hz * Output shift    ≤0.5mV * Signal noise    ≤0.5mV(P-P value,1X) * Input impedance    ≥10MΩ 3 Integrating amplifier * Integrating time   0.001-10S 4 Signal processing system* Automatic zero adjusting* Automatic gain control* Sampling rate   1-1000times/S 5 System software* File management includes file building,save,read,and the selection of communication port * Management of parameter measurement includes measurement time,high pressure of multiplier tube,gain selection,filter frequency selection,sampling rate selection * Spectra analysis includes peak value measurement(manual),area measurement(manual),spectra paste,spectra print, and data list(text format)6 Chemiluminescence unit, IFIS-A multi-function chemiluminescence detector * Wave length range   300—650nm * Sensitivity   SP>1000A/Lm 7 Sample analysis, Luminol-H2O2-Cr(III)system* Concentration detection range   1×10E-11~1×10E-5(g/mL) * Detection limit   1.5×10-12g/mL * RSD<3%(The request for trace analysis is RSD<5%; average value of RSD=S/x)

RFL-200 Ultra-weak chemiluminescence/bioluminescence detector

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.