Turbidity, color, chlorine triple multifunction analyzer
Turbidity, color, chlorine triple multifunction analyzer
Supplier Info
[China Supplier]
Contact Person : Ms. li yang
Tel : 86-392-3311689,13803929686
Fax : 86-392-33152622
Product Detail
Turbidimeter High accuracy,high sensitivity and reliability; easy to carry and operation, multifunction

Turbidity, color, chlorine triple multifunction analyzer Industry-leading accuracy, sensitivity and reliability, is one of the most innovative instrument in the measurement of turbidity, color, chlorine market. 

Features: APEX-LJ840 using infrared LED light source, in line with the requirements of the ISO 7027 standard. Is ideal for measuring low levels of drinking water and the field of high turbidity water Six detector is designed in a variety of use cases are guaranteed long-term stability Special focusing optics design Advanced infrared emission light sourceVitro positioning ring limits the location of the test bottle variability, a greater degree of sensitivity and accuracy can be obtained The MSP430 microcontroller handheld applications on the market, the most advanced controller, using advanced calibration algorithms Supports six languages: English, Spanish, French, Japanese, Italian and Portuguese 4000 sets of data access, store the results directly on the instrument tour or download to your PC Compatible with existing Smart Link 2 software Graphic LCD display, easy to read Simple menu prompts Instrument characteristics 

Battery: 9V 
AC Power Supply: Optional 
Data Access:4000 sets 
Automatic shutdown: None, 5, 10, 30 
Language:English, Spanish, French, Japanese, Italian, and Portuguese 
Response time:<5 seconds 

Turbidity Design standards in line with the use of optical turbidimeter turbidity quantitative method ISO 7027/EPA 180.1 Use of micro-focusing optics Two users to select the factory calibration mode - Formalin - Japan polystyrene turbidity mode (Japanese waterworks Rules) Formalin, a styrene divinyl benzene beads suspension (AMCO), can easily be precise field calibration The average time of a user selection signal (none, 2,5 or 10) At very low turbidity levels, improve accuracy, with no turbidity of the water as a blank, 0:00 calibration and allows Parameters: Measurement modes: NTU / FNU / FAU / ASBC / EBC Range :0-4000 Resolution: 0.01NTU/FNU 0.00-10.99 0.1 NTU / FNU 11.00-109.9 1 NTU / FNU 110-4000 Accuracy: ± 2% Detection limit: 0.05 NTU / FNU Range selection: automatic Repeatability: 0.02 NTU / FNU 0.5 FAU Stray light: <0.02NTU FNU Light Source: 860nm LED (ISO) Tungsten lamp (EPA) The average time of the signal: No, 2, 5, 10 Residual chlorine To transcend EPA330.5 design standards Liquid and tablet DPD chlorine and total chlorine calibration To complete a wide range of measurement with the same sample cell and reagent dosage Low concentrations detected User selectable modes ppm or mg / L Parameter Range :0-10ppm Resolution: 0.01ppm (0-5) / 0.1ppm (5-10) Accuracy: 0.05 or ± 2% Detection limit: 0.02ppm Response time: <5 seconds Light Source: 525nm LED Chroma UV LED and micro-focusing optics can achieve a low detection limit Turbidity and chlorine test using the same vial Parameter Range :0-500cu Resolution: 0.1cu (0-99.9cu) Accuracy: ± 0.5cu or 2% Detection limit: 0.2cu Response time: <5 seconds Light Source: UV LED 375nm 

Turbidity, color, chlorine triple multifunction analyzer