Generator controller 1.Automatic start module 2.assembles digitization, intelligentization and networked techniques.

AMF generator controllers HGM6320G

HGM6300G Series generator controller integrating digital, intelligent and network techniques is used for automatic control system of diesel generator. Also have GSM the message remote control and message warn the function of hinting .It can carry out functions including automatic start/stop, data measure and alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. 

HGM6300G Series generator controller uses micro-processing technique which can carry out precision measure, constant value adjustment, timing and threshold setting and etc. of multi-parameters. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability. 

1. Performance and characteristics HGM6300 controller has two types:

HGM6310: ASM (Automatic Start Module)

HGM6320: AMF (Automatic Mains Failure Module)

 Using microprocessor as a core, graphics LCD with big screen and backlight, display between Chinese and English, key touch for operation. Precision measure and display of

mains voltage

mains frequency (Hz)

mains active power (kW)

mains apparent power (kVA)

mains power factor

generator voltage

generator current

generator frequency (Hz)

generator active power (kW)

generator apparent power (kVA)

generator power factor

generator hours count

generator cumulate electric energy (kWh)

generator temperature

generator pressure

generator fuel level

start battery voltage

 Configurable single phase 2 wires or three phase 3 wires or three phase 4 wires AC system input; Have message function; can setting 5 move correspond by letter terminal and controller correspondence. Can use to move correspondence terminal to send out an order to carry on a control to the controller, and when have the warning occurrence of constitution will return to move correspondence terminal; Control protection: Automatic start/stop, load transfer and alarming of generator; Parameters setting: Allow user to modify setting and store them inside internal FLASH memory, the parameters cannot be lost even with power down.  Three channel analog inputs, may joint with Resistive-type temperature/ pressure/ fuel level sensors, Several temperature and pressure sensors can be used directly (ie. VDO, DATCON, CUMMINS), also may select “user defined” sensor via entering 16 point curves; Functions including RTC(real time clock) and hours count; Display of generator cumulated electric energy; Security password-protected programming levels.  Several crank success conditions are optional; Built-in speed/frequency detecting units can accurately judge the states such as crank success and over speed; 99 historical records can be stored circularly and inquiring of the records can be made on site; Power supply range is wide, accommodating to different starting battery voltage environments; All parameters use digital modulation, abandoning analog modulation using conventional electronic potentiometer, reliability and stability are increased; Specification

Operating Voltage

DC8. 0V to 35. 0V, Continuous Power Supply

Power Consumption

<3W

Alternator Input Range

Single phase 2 wire

3-Phase 4 Wire

3-Phase 3 Wire

2-Phase 3 Wire

15V AC - 360 V AC (ph-N)

15V AC - 360 V AC (ph-N)

30V AC - 600 V AC (ph-ph)

30V AC - 600 V AC (ph-ph)

Alternator Input Frequency

50Hz - 60 Hz at rated engine speed

Magnetic Input Range

+/- 0. 5 V to 70 V Peak

Magnetic Input Frequency

10,000 Hz (max) at rated engine speed. 

Start Relay Output

16 Amp DC at supply voltage. 

Fuel Relay Output

16 Amp DC at supply voltage. 

Auxiliary Relay Output (1-4)

(1-3)16 Amp DC at supply voltage,(4)6A 250VAC

Close Mains Relay

16A 250VAC free voltage contact

Close Generator Relay

16A 250VAC free voltage contact

Dimensions

240mm x 172mm x 57mm

Panel cutout

216mm x 160mm

Charge Fail / Excitation Range

0 V to 35 V

Operating Temperature Range

-25 to +70°C

Storage Condition

Temperature: (-40 to+ 70)°C

C. T. Burden

2. 5VA

C. T. Secondary

5A

Weight

0. 90kg