Welcome to ECVERY
Kinco FV100 Series VFD
Kinco FV100 Series VFD
Supplier Info
[China Supplier]
Contact Person : Ms. Wang Liz
Tel : 86-21-68798588
Fax : 86-21-68797688
Product Detail
1. Vector with PG, V/F control 2. Output Frequency Range: 0-300.0 Hz 3. 3PH AC 380~ 440V, 50 / 60Hz 4. Customized VFD

Kinco Frequency Inverter  integrates the characteristics of compact design, easy operation, and effective cost, including MV100 Series, EV100 Series, FV100 Series and SV100 Series. The functions such as unique over current, stall and torque protection make Kinco VFD work smoothly and safely.

FV100 Series has three control methods: closed vector loop, open vector loop and V/F.

Rated Voltage/Frequency: 3PH  AC 380~ 440V, 50 / 60HzControl Method: Vector control without PG, Vector control with PG, and V/F controlOutput Frequency Range: 0~300.0 HzFrequency Accuracy: Digital setting: Max frequency * ±0.01%, Analog setting: Max. frequency * ±0.2%

Parameter of FV100 Series VFD:

Key technology data and function
InputRated input voltage(V)Three-phase, 380V~440V AC;Fluctuation range:-15% ~ +10%; Voltage unbalancedness:<3%, distortion rate satisfies the IEC61800-2 demand
Rated frequency50Hz/60Hz; Fluctuation range: ±5%
OutputFrequency0Hz~300Hz. V/F: maximum 1000Hz (Custom made), others: 650Hz (Custom made)
Overload capacityG Type:150% rated  current 1 minute,  180% rated current 10 seconds
Control methodVector control without PG,  Vector control with PG,  V/F control
Speed range1:200(Vector control without PG), 1:5000(Vector control with PG)
Speed control accuracy0.2%(Vector control without PG), 0.02%(Vector control with PG)
Speed fluctuation0.3%(Vector control without PG), 0.1%(Vector control with PG)
Frequency accuracyDigital setting:Max frequency ×±0.01%;Analog setting: Max. frequency ×±0.2%
Starting torque0.5Hz 150%rated torque (Vector control without PG),  0Hz 200% rated torque (Vector control with PG)
Torque response<20ms(Vector control without PG), <10ms(Vector control with PG)
Torque controlVector control with PG ,  accuracy: 5%
ExpansionSupport multi-function expansion
ControlfeaturesMain functionsInstant stop but no stop,  rapid tracking,  Over/under torque detecting,  Torque limit. Multiple speed operation,  Switch among multiple acceleration/deceleration times,Self-adjusting, S curve acceleration/deceleration,  slip difference compensation,  fan operation control, Crawl function,  jump frequency operation,  PID adjustment(sleep function),  MODBUS communication,  Drop control,  Torque control,  Switch between torque control and speed control,  Restart automatically,  Energy saving operation.
Analog inputThree channels -10V~+10V(one is differential input, other two channels support 4~20m, programmable). Resolution:10 bits
Analog outputTwo channels of 0~+10v or 4~20mA. Resolution:12 bits 
 Digital inputSeven programmable terminals
 Digital outputTwo channels OC signal outputs(programmable)(24VDC, max:50mA);A pair of programmable normally open/closed contacts
 Communication Supports MODBUS protocol, RS485
 KeyboardFive LED display, supports parameter copy function
ProtectionOver current protectionOver current,  stalling protection,  never tripping
Torque protectionOver current,  stalling protection,  never tripping
Motor protectionElectronic Inverse time limit,  can be connected to the external PTC detecting
Overload protectionInverse time limit feature, 150% 2min
Over current protectionThe drive output current is higher than the over current value,  There are acceleration, deceleration and constant speed over current.
Over voltage protectionThe detected value of bus voltage is higher than the over voltage value. There are acceleration,  deceleration and constant speed over voltage.
Over heat protectionRadiator temperature protection
Under voltage protectionThe detected value of bus voltage or control power supply voltage is under the under voltage value,  the drive gives POFF error
Stall protectionAcceleration,  deceleration and constant speed  protections can be set separately
Phase missing protection of inputDetect the phase missing of input power supply
Phase missing protection of outputDetect the phase missing of inverter output 
Short circuit protection to earth or between two phasesDetect the short circuit to earth or between two phases
Fault detect of brake unitDetect the fault of the brake unit
OthersBrake unitBuilt- in if power is under 37KW
DC reactoroptional
EMI filter EMI filter, IEC61800-3C1(EN55011CLASSB)10 meters, IEC61800-3C2(EN55011CLASSA)50 meters/100 meters
Ambient temperature0°C~+40°C, when temperature is higher than 40°C,  the rated value should be reduced
Humidity5%~95%
Protection classIP20
Installation method Power under 90kw supports through installation
Bus connectorSupports RS485, CAN