It produces ions with velocity air to neutralize the static charge. Ionizing points are cased in a rigid aluminum bar. It is rugged construction allows it to have excellent performance on removing contamination and neutralizing static charge. It requires our Airsource 403A power supply for operation, which must be ordered separately.
Specification
HV Cable length | 3000mm |
Operating Temperature | 20~50degrees |
Min & Max. Length | 200mm & 1300mm |
Relative Humidity | <60% RH |
Current consumption | 0.04mA/m |
Decay Test Results :
Distance
| Decay Time |
Without compressed air | |
20mm | 0.2s |
40mm | 0.2s |
60mm | 0.6s |
Testing Voltage 5Kv to 500v |
Ionizing Air Bar